BACKGROUND AND

OBJECTIVE

Normative values for HAA-a quantitative, CT-based measure of subclinical ILD-in healthy adults are needed to improve interpretability in clinical and research settings.

METHODS

HAA was measured on full-lung CT in 3110 participants in the MESA study. Clinical prediction models were developed using a healthy never-smoker subset with normal spirometry (n = 696). RMSE on cross-validation was used as the primary criterion for model selection. Parametric and non-parametric methods were considered. z-Scores were calculated for the entire study sample. Associations between z-scores and several ILD features were estimated.

RESULTS

In the healthy never-smoker subset, the mean age was 69 years with a range of 54-93 years. The median HAA was 4.3% with a range of 2.7-17.8%. Linear regression had better predictive performance than other methods. The final model included race, height, weight, age and sex. The standard error of the estimate was 1.62 with a cross-validated RMSE of 1.64 and an adjusted R2 of 0.139. z-Scores were associated with several ILD outcomes in adjusted models, including ILA (OR: 1.40 per z-unit; 95% CI: 1.30, 1.52), exertional dyspnoea (OR: 1.08 per z-unit; 95% CI: 1.02, 1.15) and FVC (expected increase per z-unit: -2.49; 95% CI: -2.95, - 2.03).

CONCLUSION

We present a reference equation and z-scores to define expected values of HAA on full-lung CT to aid HAA interpretation in middle-aged and older adults.

Для цитирования: Easthausen Imaani, Podolanczuk Anna, Hoffman Eric, Kawut Steven, Oelsner Elizabeth, Kim John S, Raghu Ganesh, Stukovsky Karen Hinckley, Redline Susan, McClelland Robyn L, Barr R Graham, Lederer David J. Reference values for high attenuation areas on chest CT in a healthy, never-smoker, multi-ethnic sample: The MESA study.. Respirology (Carlton, Vic.). 2020. DOI: 10.1111/resp.13783.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.