MedElevator Войти в исследования
← Поиск публикаций

DOI 10.17420/ap7002.525

Медицинская библиотека · Annals of parasitology · 2024

Assessment of the performance of five malaria rapid diagnostic tests in health facilities in Abidjan (Côte d'Ivoire).

Konate-Toure Abibatou, Bedia-Tanoh Valérie A, Kassi Fulgence K, Vanga-Bosson Henriette, Angora Etienne K, Kone Estelle G M, Miezan Sebastien A J, Djohan Vincent, Barro-Kiki Pulcherie C M, Menan Hervé E I, Yavo William

СтатьяПеревод в очереди

Аннотация

Regular monitoring of malaria rapid diagnostic tests (RDTs) for the management of uncomplicated malaria in healthcare facilities is a key factor in improving diagnostic quality and ensuring better case management. This study aimed to assess the performance of five RDTs (Standard Q Malaria P.f Ag and Standard Q Malaria P.f/Pan (SD Biosensor, Korea), One Step Malaria HRP2/pLDH (P.f/Pan) (Guangzhou Wondfo Biotech Co., Ltd., China), Malaria Pf/Pan (B&O Pharm, France), and Malaria test P.f/pan (Das Labor, Germany)) in two healthcare facilities in Abidjan. This cross-sectional study was conducted between September and October 2022. Overall, 250 patients suffering from uncomplicated malaria were included with a predominance of female patients (56.6%). The mean age was 22.3 years (SD = 20.6; range, 0.17-73). Of the patients tested, forty-six (46) tested positive for thick smears, reflecting a prevalence of 18.5%. Plasmodium falciparum was the most commonly detected species (93.5%). The geometric mean parasitemia was 6,111.80 parasites/μl (SD = 80,026.93) (range: 116-412461). The sensitivity ranged from 95.24% to 95.65%, whereas the specificity ranged from 93.07 to 94.09% for all five tests evaluated. The false positive rate of the tests was less than 10%. No invalid test results were reported. Two-thirds of P. malariae cases detected by microscopy showed also positive results with all the RDTs. All five RDTs showed 100% sensitivity at low parasitemia levels (< 1,000 parasites/μl blood) including three cases of parasites < 200 parasites/μl blood. This study demonstrated the importance of monitoring the performance of RDTs in clinical samples.

Для цитирования: Konate-Toure Abibatou, Bedia-Tanoh Valérie A, Kassi Fulgence K, Vanga-Bosson Henriette, Angora Etienne K, Kone Estelle G M, Miezan Sebastien A J, Djohan Vincent, Barro-Kiki Pulcherie C M, Menan Hervé E I, Yavo William. Assessment of the performance of five malaria rapid diagnostic tests in health facilities in Abidjan (Côte d'Ivoire).. Annals of parasitology. 2024. DOI: 10.17420/ap7002.525.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.