MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcms.2019.04.003

Медицинская библиотека · Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2019

Comparison of postoperative skeletal stability of maxillary segments after Le Fort I osteotomy, using patient-specific implant versus mini-plate fixation.

Kotaniemi Karoliina V M, Heliövaara Arja, Kotaniemi Miika, Stoor Patricia, Leikola Junnu, Palotie Tuula, Suojanen Juho

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Three-dimensionally (3D) designed osteotomies and customised osteosynthesis are rapidly becoming standard in maxillofacial reconstructive and deformity surgery. Patient-specific implants (PSIs) have been in use for a few years in orthognathic surgery as well. In Le Fort I osteotomy, wafer-free fixation of the maxillary segment can be performed by individually manufactured cutting and drill guides together with PSIs.

AIM: This retrospective study was performed to compare the postoperative skeletal stability of the maxillary segment fixed by patient-specific implants versus mini-plates after Le Fort I osteotomy.

PATIENTS: Fifty-one patients were divided into subgroups according to the fixation method and the advancement of the sub-spinal point. The postoperative skeletal stability of the maxillary segment was evaluated from lateral cephalometric radiographs one year postoperatively.

RESULTS

No statistically significant differences were found between the postoperative skeletal stability of the PSI and mini-plate fixed maxillae. Prospective studies, possibly with 3D fusion analysis, are warranted to confirm the results.

CONCLUSION

The choice between the two fixation methods does not seem to affect the postoperative skeletal stability of the maxillary segments.

Для цитирования: Kotaniemi Karoliina V M, Heliövaara Arja, Kotaniemi Miika, Stoor Patricia, Leikola Junnu, Palotie Tuula, Suojanen Juho. Comparison of postoperative skeletal stability of maxillary segments after Le Fort I osteotomy, using patient-specific implant versus mini-plate fixation.. Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery. 2019. DOI: 10.1016/j.jcms.2019.04.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.