m+Medelevator.RU
← Поиск публикаций
Sleep · 2009

Abdominal compression increases upper airway collapsibility during sleep in obese male obstructive sleep apnea patients.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Stadler Daniel L, McEvoy R Doug, Sprecher Kate E, Thomson Kieron J, Ryan Melissa K, Thompson Courtney C, Catcheside Peter G

Аннотация

STUDY OBJECTIVES: Abdominal obesity, particularly common in centrally obese males, may have a negative impact on upper airway (UA) function during sleep. For example, cranial displacement of the diaphragm with raised intra-abdominal pressure may reduce axial tension exerted on the UA by intrathoracic structures and increase UA collapsibility during sleep.

DESIGN: This study aimed to examine the effect of abdominal compression on UA function during sleep in obese male obstructive sleep apnea patients.

SETTING: Participants slept in a sound-insulated room with physiologic measurements controlled from an adjacent room.

PARTICIPANTS: Fifteen obese (body mass index: 34.5 +/- 1.1 kg/m2) male obstructive sleep apnea patients (apnea-hypopnea index: 58.1 +/- 6.8 events/h) aged 50 +/- 2.6 years participated.

INTERVENTIONS: Gastric (PGA) and transdiaphragmatic pressures (P(DI)), UA closing pressure (UACP), UA airflow resistance (R(UA)), and changes in end-expiratory lung volume (EELV) were determined during stable stage 2 sleep with and without abdominal compression, achieved via inflation of a pneumatic cuff placed around the abdomen. UACP was assessed during brief mask occlusions.

MEASUREMENTS AND RESULTS: Abdominal compression significantly decreased EELV by 0.53 +/- 0.24 L (P=0.045) and increased PGA (16.2 +/- 0.8 versus 10.8 +/- 0.7 cm H2O, P < 0.001), P(DI) (11.7 +/- 0.9 versus 7.6 +/- 1.2 cm H2O, P < 0.001) and UACP (1.4 +/- 0.8 versus 0.9 +/- 0.9 cm H2O, P = 0.039) but not R(UA)(6.5 +/- 1.4 versus 6.9 +/- 1.4 cm H2O x L/s, P=0.585).

CONCLUSIONS: Abdominal compression negatively impacts on UA collapsibility during sleep and this effect may help explain strong associations between central obesity and obstructive sleep apnea.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты