MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00247-012-2572-2

Медицинская библиотека · Pediatric radiology · 2012

White matter integrity on fractional anisotropy maps in encephalopathic neonates post hypothermia therapy with normal-appearing MR imaging.

Lee Earn Chun Christabel, Kwatra Neha S, Vezina Gilbert, Khademian Zarir P

Контролируемое клиническое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Neonatal encephalopathy (NE) is a clinically defined neurological syndrome commonly caused by ischemia.

OBJECTIVE

We investigated white matter integrity in children with NE using diffusion tensor imaging (DTI) and examined the hypothesis that white matter insults not visible on conventional MRI may have abnormal fractional anisotropy (FA) on DTI.

MATERIALS AND

METHODS

DTI was performed on 36 term encephalopathic neonates who had hypothermia therapy. Of these, 12 neonates had normal conventional MRI findings (NNE) and 24 neonates had abnormal MRI findings (ANE). Twelve term-equivalent premature neonates with normal clinical neuroimaging and neurological function served as the control group.

RESULTS

We found significant reductions in measured FA in white matter in the ANE neonates compared to the control group. There were, however, no significant differences in measured FA in white matter between the NNE and the control group.

CONCLUSION

We did not find white matter changes detectable by DTI in encephalopathic neonates post hypothermia with normal conventional MRI findings. Further studies would be required to determine whether this unexpected finding is a direct result of neuroprotective effects of hypothermia, or more sophisticated measures of FA are required to detect subtle white matter injury.

Для цитирования: Lee Earn Chun Christabel, Kwatra Neha S, Vezina Gilbert, Khademian Zarir P. White matter integrity on fractional anisotropy maps in encephalopathic neonates post hypothermia therapy with normal-appearing MR imaging.. Pediatric radiology. 2012. DOI: 10.1007/s00247-012-2572-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.