Sonographic measurement of diuretic-induced renal length changes: are they correlated with renal function?

Akgun Veysel, Battal Bilal, Kocaoglu Murat, Ozcan Emrah, Akay Sinan, Ilgan Seyfettin

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

The purposes of this study were to prospectively identify diuretic-induced renal length changes and to determine whether the percentages of the renal length changes allow estimation of the differential renal function.

METHODS

Twenty-three children (14 boys and 9 girls; mean age, 7.83 years) who were undergoing technetium Tc 99m diethylenetriamine pentaacetic acid or technetium Tc 99m mercaptoacetyltriglycine diuretic renography were included in this study. Renal lengths were measured by sonography just before and 15 to 20 minutes after diuretic injection. The Spearman test was used to assess the correlation between renal length increases due to diuretic injection and the differential renal function.

RESULTS

The mean renal lengths ± SD measured before and after diuretic administration were 91.52 ± 20.87 and 95.38 ± 21.46 mm, respectively. The increase in renal length after diuretic administration was statistically significant (P < .001). There was a positive correlation between the renal length change and functional status (P = .006).

CONCLUSIONS

Renal length may change after diuretic injection according to the functional status, and the sonographic measurements of these changes may be used as an alternative to other imaging methods in estimation of renal function.

Для цитирования: Akgun Veysel, Battal Bilal, Kocaoglu Murat, Ozcan Emrah, Akay Sinan, Ilgan Seyfettin. Sonographic measurement of diuretic-induced renal length changes: are they correlated with renal function?. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2012. DOI: 10.7863/jum.2012.31.9.1351.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.