MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-021-07876-z

Медицинская библиотека · European radiology · 2021

Feature tracking myocardial strain analysis in patients with bileaflet mitral valve prolapse: relationship with LGE and arrhythmias.

Gatti Marco, Palmisano Anna, Esposito Antonio, Fiore Stefano, Monti Caterina Beatrice, Andreis Alessandro, Pistelli Lorenzo, Vergara Pasquale, Bergamasco Laura, Giustetto Carla, De Cobelli Francesco, Fonio Paolo, Faletti Riccardo

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Anatomical substrate and mechanical trigger co-act in arrhythmia's onset in patients with bileaflet mitral valve prolapse (bMVP). Feature tracking (FT) may improve risk stratification provided by cardiac magnetic resonance (CMR). The aim was to investigate differences in CMR and FT parameters in bMVP patients with and without complex arrhythmias (cVA and no-cVA).

METHODS

In this retrospective study, 52 patients with bMVP underwent 1.5 T CMR and were classified either as no-cVA (n = 32; 12 males; 49.6 ± 17.4 years) or cVA (n = 20; 3 males; 44.7 ± 11.2 years), the latter group including 6 patients (1 male; 45.7 ± 12.7 years) with sustained ventricular tachycardia or ventricular fibrillation (SVT-FV). Twenty-four healthy volunteers (11 males, 36.2 ± 12.5 years) served as control. Curling, prolapse distance, mitral annulus disjunction (MAD), and late gadolinium enhancement (LGE) were recorded and CMR-FT analysis performed. Statistical analysis included non-parametric tests and binary logistic regression.

RESULTS

LGE and MAD distance were associated with cVA with an odds ratio (OR) of 8.51 for LGE (95% CI 1.76, 41.28; p = 0.008) and of 1.25 for MAD (95% CI 1.02, 1.54; p = 0.03). GLS 2D (- 11.65 ± 6.58 vs - 16.55 ± 5.09 1/s; p = 0.04), PSSR longitudinal 2D (0.04 ± 1.62 1/s vs - 1.06 ± 0.35 1/s; p = 0.0001), and PSSR radial 3D (3.95 ± 1.97 1/s vs 2.64 ± 1.03 1/s; p = 0.0001) were different for SVT-VF versus the others. PDSR circumferential 2D (1.10 ± 0.54 vs. 0.84 ± 0.34 1/s; p = 0.04) and 3D (0.94 ± 0.42 vs. 0.69 ± 0.17 1/s; p = 0.04) differed between patients with and without papillary muscle LGE.

CONCLUSIONS

CMR-FT allowed identifying subtle myocardial deformation abnormalities in bMVP patients at risk of SVT-VF. LGE and MAD distance were associated with cVA.

KEY POINTS: • CMR-FT allows identifying several subtle myocardial deformation abnormalities in bMVP patients, especially those involving the papillary muscle. • CMR-FT allows identifying subtle myocardial deformation abnormalities in bMVP patients at risk of SVT and VF. • In patients with bMVP, the stronger predictor of cVA is LGE (OR = 8.51; 95% CI 1.76, 41.28; p = 0.008), followed by MAD distance (OR = 1.25; 95% CI 1.02, 1.54; p = 0.03).

Для цитирования: Gatti Marco, Palmisano Anna, Esposito Antonio, Fiore Stefano, Monti Caterina Beatrice, Andreis Alessandro, Pistelli Lorenzo, Vergara Pasquale, Bergamasco Laura, Giustetto Carla, De Cobelli Francesco, Fonio Paolo, Faletti Riccardo. Feature tracking myocardial strain analysis in patients with bileaflet mitral valve prolapse: relationship with LGE and arrhythmias.. European radiology. 2021. DOI: 10.1007/s00330-021-07876-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.