Reliability of gait performance tests in individuals with late effects of polio.

Flansbjer Ulla-Britt, Lexell Jan

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To assess the reliability of 4 gait performance tests in individuals with late effects of polio.

DESIGN

An intrarater (between occasions) test-retest reliability study.

SETTINGS: University hospital.

PARTICIPANTS

Thirty men and women (mean age 63 +/- 6.4 years) with clinically and electrophysiologically verified late effects of polio.

INTERVENTION: Not applicable.

MAIN OUTCOME MEASURES: The Timed "Up & Go" test, the Comfortable and the Fast Gait Speed tests, and the 6-Minute Walk test were assessed 7 days apart. Reliability was evaluated with the intraclass correlation coefficient (ICC(2,1)), the mean difference between the test sessions (d), and the 95% confidence intervals for d, the standard error of measurement (SEM and SEM%), the smallest real difference (SRD and SRD%) and the Bland & Altman graphs.

RESULTS

Test-retest agreements were high (ICC(2,1) 0.82-0.97) and measurement errors generally small. The standard error of measurement (SEM%), representing the smallest change that indicates a real (clinical) improvement for a group of individuals, was small (4%-7%). The smallest real difference (SRD%), representing the smallest change that indicates a real (clinical) improvement for a single individual also was small (12%-21%).

CONCLUSION

These commonly used gait performance tests are highly reliable and can be recommended to evaluate improvements in various aspects of gait performance in groups of individuals as well as single individuals with late effects of polio.

Для цитирования: Flansbjer Ulla-Britt, Lexell Jan. Reliability of gait performance tests in individuals with late effects of polio.. PM & R : the journal of injury, function, and rehabilitation. 2010. DOI: 10.1016/j.pmrj.2009.12.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.