DOI 10.1007/s00383-021-04876-4
Comparison of non-invasive physiological assessment tools between simple and perforated appendicitis in children.
Аннотация
PURPOSE: The role of non-invasive measures of physiologic reserve, specifically the Compensatory reserve index (CRI) and the Shock index pediatric age-adjusted (SIPA), is unknown in the management of children with acute appendicitis. CRI is a first-in-class algorithm that uses pulse oximetry waveforms to continuously monitor central volume status loss. SIPA is a well-validated, but a discontinuous measure of shock that has been calibrated for children.
METHODS
Children with suspected acute appendicitis (2-17 years old) were prospectively enrolled at a single center from 2014 to 2015 and monitored with a CipherOx CRI™ M1 pulse oximeter. CRI values range from 1 (normovolemia) to 0 (life-threatening hypovolemia). SIPA is calculated by dividing heart rate by systolic blood pressure and categorized as normal or abnormal, based on age-specific cutoffs. Univariate and multivariable regression models were developed with simple versus perforated appendicitis as the outcome.
RESULTS
Almost half the patients (45/94, 48%) had perforated appendicitis. On univariate analysis, the median admission CRI value was significantly higher (0.60 versus 0.33, p < 0.001) and the ED SIPA values were significantly lower (0.90 versus 1.10, p = 0.002) in children with simple versus perforated appendicitis. In a multivariable model, only CRI significantly detected differences in the physiologic state between patients with simple and perforated appendicitis.
CONCLUSIONS
CRI is a non-invasive measure of physiologic reserve that may be used to accurately guide early management of children with acute simple versus perforated appendicitis.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.