MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1525-1594.2008.00549.x

Медицинская библиотека · Artificial organs · 2008

Hip orthosis powered by pneumatic artificial muscle: voluntary activation in absence of myoelectrical signal.

do Nascimento Breno Gontijo, Vimieiro Claysson Bruno Santos, Nagem Danilo Alves Pinto, Pinotti Marcos

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Powered orthosis is a special class of gait assist device that employs a mechanical or electromechanical actuator to enhance movement of hip, knee, or ankle articulations. Pneumatic artificial muscle (PAM) has been suggested as a pneumatic actuator because its performance is similar to biological muscle. The electromyography (EMG) signal interpretation is the most popular and simplest method to establish the patient voluntary control of the orthosis. However, this technique is not suitable for patients presenting neurological lesions causing absence or very low quality of EMG signal. For those cases, an alternative control strategy should be provided. The aim of the present study is to develop a gait assistance orthosis for lower limb powered by PAMs controlled by a voluntary activation method based on the angular behavior of hip joint. In the present study, an orthosis that has been molded in a patient was employed and, by taking her anthropometric parameters and movement constraints, the adaptation of the existing orthosis to the powered orthosis was planned. A control system was devised allowing voluntary control of a powered orthosis suitable for patients presenting neurological lesions causing absence or very low quality of EMG signal. A pilot clinical study was reported where a patient, victim of poliovirus, successfully tested a hip orthosis especially modified for the gait test evaluation in the parallel bar system. The hip orthosis design and the control circuitry parameters were able to be set to provide satisfactory and comfortable use of the orthosis during the gait cycle.

Для цитирования: do Nascimento Breno Gontijo, Vimieiro Claysson Bruno Santos, Nagem Danilo Alves Pinto, Pinotti Marcos. Hip orthosis powered by pneumatic artificial muscle: voluntary activation in absence of myoelectrical signal.. Artificial organs. 2008. DOI: 10.1111/j.1525-1594.2008.00549.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.