DOI 10.1097/bot.0b013e3182694766

Медицинская библиотека · Journal of orthopaedic trauma · 2013

A reliable method for intraoperative evaluation of syndesmotic reduction.

Summers Hobie D, Sinclair Micah K, Stover Michael D

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To determine the accuracy of a technique for intraoperative assessment of syndesmotic reduction in ankle fractures.

DESIGN

Prospective, case series.

SETTING

University hospital.

PATIENTS/

PARTICIPANTS

Eighteen consecutive patients with suspected syndesmotic injuries were enrolled between 2007 and 2009. The diagnosis of syndesmotic injury was based on static ankle radiographs. The study group consisted of 12 male and 6 female patients with an average age of 32 years (range 19-56 years).

INTERVENTION: All patients had mortise and talar dome lateral fluoroscopic images obtained of the uninjured ankle in the operating room. The injured ankle underwent operative reduction and provisional fixation using the uninjured ankle radiographs as a template for comparison. An intraoperative computed tomography (CT) scan was obtained to verify the syndesmotic reduction before syndesmotic fixation. If the reduction was not anatomic, the reduction was revised using fluoroscopy and the CT repeated.

MAIN OUTCOME MEASUREMENTS: Accuracy of syndesmotic reduction performed using fluoroscopy and confirmed by intraoperative CT scan.

RESULTS

Using the technique described, intraoperative CT confirmed anatomic reduction initially in 17 of the 18 fractures. The 1 case where CT did change the course of treatment, revision of fibular fracture reduction resulted in an anatomic reduction of the syndesmosis on repeat CT.

CONCLUSIONS

Accurate evaluation of the syndesmotic reduction can be determined intraoperatively using comparison mortise and talar dome lateral fluoroscopic images. Direct visualization of the syndesmosis or CT may not be necessary to achieve an accurate reduction in these injuries.

Для цитирования: Summers Hobie D, Sinclair Micah K, Stover Michael D. A reliable method for intraoperative evaluation of syndesmotic reduction.. Journal of orthopaedic trauma. 2013. DOI: 10.1097/bot.0b013e3182694766.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.