MedElevator Войти в исследования
← Поиск публикаций

DOI 10.11604/pamj.2021.38.29.26111

Медицинская библиотека · The Pan African medical journal · 2021

Myocardial performance after coronary re-implantation in pediatric patients assessed with conventional echocardiographic and 2D-speckle tracking analysis: a case-control study.

Charfeddine Salma, Abid Dorra, Hammami Rania, Gargouri Rania, Abid Leila, Triki Faten, Kammoun Samir

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

INTRODUCTION

reduced exercise capacity, coronary artery abnormalities and reversible myocardial ischemia have been demonstrated after arterial switch operation (ASO) and coronary reimplantation. Despite this, indices of systolic function, assessed by standard and Doppler echocardiography, are within the normal range. The aim of this study was to highlight the long-term changes in myocardial function following coronary reimplantation using Doppler and speckle-tracking imaging (STI) echocardiography.

METHODS

this observational case control study included 36 patients and 20 gender and age-matched healthy controls. A group study was performed using patients who were followed for at least 6 months after the operation and who visited the pediatric cardiology outpatient between October 2015 and May 2016. Systolic and diastolic parameters, left ventricle (LV) and right ventricle (RV) myocardial performance were assessed in each group.

RESULTS

the LV global peak strain parameters revealed a significant decrease in the longitudinal and circumferential strain components. The LV global longitudinal strain (GLS) values were lower in both groups of operated patients than controls (-19.9 ± 2.2% (group 1) versus -20.9 ± 1.6% (group 2) versus -22.9 ± 2.3% (group 3), p<0.001). The patients with coronary reimplantation had the lowest values. The LV global circumferential strain was also decreased in the group 1 patients as compared with the 2 other groups (-16.6 ± 4.1% (group 1) versus -19.4 ± 3.9% (group 2) versus -19.8 ± 4.0% (group 3), p<0.001).

CONCLUSION

although global LV function, assessed with conventional echocardiographic parameters, was normal, the 2D-STI analysis showed slight but significant decrease in the global and segmental longitudinal and circumferential LV strain during the long-term follow-up after coronary arteries reimplantation.

Для цитирования: Charfeddine Salma, Abid Dorra, Hammami Rania, Gargouri Rania, Abid Leila, Triki Faten, Kammoun Samir. Myocardial performance after coronary re-implantation in pediatric patients assessed with conventional echocardiographic and 2D-speckle tracking analysis: a case-control study.. The Pan African medical journal. 2021. DOI: 10.11604/pamj.2021.38.29.26111.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.