MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcv.2020.104539

Медицинская библиотека · Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2020

Performance evaluation of Abbott ARCHITECT SARS-CoV-2 IgG immunoassay in comparison with indirect immunofluorescence and virus microneutralization test.

Meschi Silvia, Colavita Francesca, Bordi Licia, Matusali Giulia, Lapa Daniele, Amendola Alessandra, Vairo Francesco, Ippolito Giuseppe, Capobianchi Maria Rosaria, Castilletti Concetta, INMICovid-19 laboratory team

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Serological tests for anti-SARS-CoV-2 antibodies are becoming of great interest to determine seroprevalence in a given population, define previous exposure and identify highly reactive human donors for the generation of convalescent serum as therapeutic.

OBJECTIVES

We evaluated the diagnostic performance of the Abbott ARCHITECT SARS-CoV-2 IgG test, a fully automated indirect immunoassay that detects antibodies directed to a recombinant SARS-CoV-2 Nucleocapsid antigen.

STUDY

DESIGN

Abbott ARCHITECT SARS-CoV-2 IgG immunoassay was compared to an indirect immunofluorescence assay (IFA) on sera from patients with COVID-19 collected at different days after symptoms onset or infected by other human coronaviruses. Comparison with neutralization test was also performed.

RESULTS

After 7, 14 and >14 days after onset ARCHITECT was positive on 8.3 %; 61.9 % and 100 % of the tested samples compared to 58.3 %; 85.7 % and 100 % by IFA. The sensitivity was 72 % vs. IFA and 66.7 % vs. a real-time PCR, the specificity was 100 %. On 18 samples with neutralizing activity, 17 were positive by Abbott ARCHITECT SARS-CoV-2 IgG.

CONCLUSIONS

In our study, Abbott ARCHITECT SARS-CoV-2 IgG assay showed a satisfactory performance, with a very high specificity. IgG reactivity against SARSCoV-2 N antigen was detectable in all patients by two weeks after symptoms onset. In addition, concordance between this serological response and viral neutralization suggests that a strong humoral response may be predictive of a neutralization activity, regardless of the target antigens. This finding supports the use of this automated serological assay in diagnostic algorithm and public health intervention, especially for high loads of testing.

Для цитирования: Meschi Silvia, Colavita Francesca, Bordi Licia, Matusali Giulia, Lapa Daniele, Amendola Alessandra, Vairo Francesco, Ippolito Giuseppe, Capobianchi Maria Rosaria, Castilletti Concetta, INMICovid-19 laboratory team. Performance evaluation of Abbott ARCHITECT SARS-CoV-2 IgG immunoassay in comparison with indirect immunofluorescence and virus microneutralization test.. Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology. 2020. DOI: 10.1016/j.jcv.2020.104539.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.