MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5830/cvja-2011-004

Медицинская библиотека · Cardiovascular journal of Africa · 2012

Total correction in tetralogy of Fallot with anomalous major coronary artery: an alternative method to conduit use.

Saritas B, Ozker E, Vuran E, Yoruker U, Ayabakan C, Turkoz R

Клинический случайСтатьяПеревод в очереди

Аннотация

INTRODUCTION

A coronary artery anomaly precludes the use of a trans-annular patch in right ventricular outflow tract (RVOT) reconstruction. Herein we present three patients with coronary artery anomalies who underwent total corrective operations without using a conduit.

METHODS

Between 2007 and 2010, 84 patients with tetralogy of Fallot (TOF) were operated on. Nine (9.4%) of them had a coronary artery anomaly. Three (3.1%) of the patients were operated on using the double-outflow technique and two had a Blalock-Taussig shunt before the total corrective operation. In two patients, the left anterior descending artery (LAD) and in one, the right coronary artery (RCA) crossed the RVOT.

RESULTS

Postoperatively, the right-to-left ventricular pressure ratios were 0.45, 0.59 and 0.60 after cardiopulmonary bypass. No gradient was detected in the RVOT in postoperative echocardiographical measurements (< 15 mmHg gradient). In all three patients, there were moderate pulmonary insufficiencies. All were discharged home on the sixth day postoperatively. Mean follow-up duration was 9.8 ± 8 months. In the follow up of all three patients, there were moderate pulmonary insufficienciencies but no right ventricular dysfunction.

CONCLUSION

The 'double-outflow' technique is appropriate for TOF patients with a major coronary artery anomaly since it can easily be performed without the need of a conduit.

Для цитирования: Saritas B, Ozker E, Vuran E, Yoruker U, Ayabakan C, Turkoz R. Total correction in tetralogy of Fallot with anomalous major coronary artery: an alternative method to conduit use.. Cardiovascular journal of Africa. 2012. DOI: 10.5830/cvja-2011-004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление