MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11604-011-0594-6

Медицинская библиотека · Japanese journal of radiology · 2011

Usefulness of electrocardiography-gated dual-source computed tomography for evaluating morphological features of the ventricles in children with complex congenital heart defects.

Nakagawa Motoo, Hara Masaki, Sakurai Keita, Ohashi Kazuya, Asano Miki, Shibamoto Yuta

СтатьяПеревод в очереди

Аннотация

PURPOSE: Improved time resolution using dual-source computed tomography (DSCT) enabled adaptation of electrocardiography (ECG)-gated cardiac CT for children with a high heart rate. In this study, we evaluated the ability of ECG-gated DSCT (ECG-DSCT) to depict the morphological ventricular features in patients with congenital heart disease (CHD).

MATERIALS AND

METHODS

Between August 2006 and March 2010, a total of 66 patients with CHD (aged 1 day to 9 years, median 11 months) were analyzed using ECG-DSCT. The type of anomaly was ventricular septal defect (VSD) in 32 (malaligned type in 20, perimembranous type in 7, supracristal type in 3, muscular type in 2), single ventricle (SV) in 11, and corrected transposition of the great arteries (cTGA) in 3. All patients underwent ECG-DSCT and ultrasonography (US). We evaluated the accuracy of diagnosing the type of VSD. For the cases with SV and cTGA, we evaluated the ability to depict anatomical ventricular features.

RESULTS

In all 32 cases of VSD, DSCT could confirm the VSD defects, and the findings were identical to those obtained by US. Anatomical configurations of the SV and cTGA were correctly diagnosed, similar to that on US.

CONCLUSION

Our study suggests that ECG-DSCT can clearly depict the configuration of ventricles.

Для цитирования: Nakagawa Motoo, Hara Masaki, Sakurai Keita, Ohashi Kazuya, Asano Miki, Shibamoto Yuta. Usefulness of electrocardiography-gated dual-source computed tomography for evaluating morphological features of the ventricles in children with complex congenital heart defects.. Japanese journal of radiology. 2011. DOI: 10.1007/s11604-011-0594-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.