Ophthalmology · 2006
Angle closure in highly myopic eyes.
Клинический случайСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Barkana Yaniv, Shihadeh Wisam, Oliveira Cristiano, Tello Celso, Liebmann Jeffrey M, Ritch Robert
Аннотация
PURPOSE: Patients with angle-closure glaucoma and high myopia are uncommon. We evaluated the clinical characteristics of all patients with angle closure and high myopia in our database and propose possible mechanisms for angle closure in these atypical patients.
DESIGN: Retrospective noncomparative case series.
PARTICIPANTS: Our database of 17938 patients was searched for patients with myopia of spherical equivalent of more than -6.0 diopters and angle closure. Data recorded included age at time of initial consultation, gender, slit-lamp examination results, gonioscopy results, biometric parameters, ultrasound biomicroscopy results (from 1993 onward), clinical diagnosis, and therapy.
RESULTS: Twenty patients (11 females, 9 males) were identified. Mean age at the time of consultation was 52.9+/-19.3 years. Angle-closure diagnoses included primary pupillary block (9 patients), pupillary block in an eye with keratoconus (1 patient), pupillary block secondary to a pupillary membrane associated with retinopathy of prematurity (1 patient), plateau iris configuration and syndrome (3 patients), phacomorphic glaucoma in Weill-Marchesani syndrome (2 patients), malignant glaucoma secondary to a scleral buckle (2 patients), miotic-induced angle closure (1 patient), and Marfan syndrome (1 patient).
CONCLUSIONS: Angle closure can occur in eyes with high myopia. Causes of angle closure other than relative pupillary block are more common than in the general angle-closure glaucoma population. Careful gonioscopy accompanied by biometry and ultrasound biomicroscopy can lead to the correct diagnosis and individualized management in these eyes.
DESIGN: Retrospective noncomparative case series.
PARTICIPANTS: Our database of 17938 patients was searched for patients with myopia of spherical equivalent of more than -6.0 diopters and angle closure. Data recorded included age at time of initial consultation, gender, slit-lamp examination results, gonioscopy results, biometric parameters, ultrasound biomicroscopy results (from 1993 onward), clinical diagnosis, and therapy.
RESULTS: Twenty patients (11 females, 9 males) were identified. Mean age at the time of consultation was 52.9+/-19.3 years. Angle-closure diagnoses included primary pupillary block (9 patients), pupillary block in an eye with keratoconus (1 patient), pupillary block secondary to a pupillary membrane associated with retinopathy of prematurity (1 patient), plateau iris configuration and syndrome (3 patients), phacomorphic glaucoma in Weill-Marchesani syndrome (2 patients), malignant glaucoma secondary to a scleral buckle (2 patients), miotic-induced angle closure (1 patient), and Marfan syndrome (1 patient).
CONCLUSIONS: Angle closure can occur in eyes with high myopia. Causes of angle closure other than relative pupillary block are more common than in the general angle-closure glaucoma population. Careful gonioscopy accompanied by biometry and ultrasound biomicroscopy can lead to the correct diagnosis and individualized management in these eyes.