MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Zhonghua wai ke za zhi [Chinese journal of surgery] · 2005

[Chitin biological tube bridging the peripheral nerve with a small gap].

Zhang Pei-xun, Jiang Bao-guo, Zhao Fu-qiang, Fu Zhong-guo, Zhang Dian-ying, Du Chan, Zhang Hong-bo

Аннотация на английскомСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To investigate the possibility of bridging small peripheral nerve gap using a de-acetyl chitosan conduit.

METHODS

The sciatic nerves of right sides were cut at SD rats. They were divided into 5 Groups randomly; Group A: epineurium suture in situ (n = 24); Group B: biological conduit with a small gap for bridging the peripheral nerve (n = 24, with 5 mm gap); Group C: epineurium suture with distal stump rotated 180 degrees (n = 24); Group D: bridging the nerve by biological conduits with a small gap, but the distal stump rotated 180 degrees (n = 24, with 5 mm gap); Group E: biological conduit with a small gap for bridging the peripheral nerve with NGF (n = 24). Electrophysiological examination, histological examination and myelinated axon counting were applied after 2, 4, 6, 8 weeks after operation respectively.

RESULTS

Regenerated nerve fibers were seen in the distal nerve segments of all 5 groups; The nerve conduction velocity of small gap group (group B, D) was faster than that of corresponding simple epineurium suture group (group A, C) at all 2, 4, 6, 8 week time point (P < 0.05). The myelinated axon counting of small gap group (group B, D) was faster than that of corresponding simple epineurium suture group (group A, C) at all 4, 6, 8 week time point (P < 0.01), and there was no statistically significant difference at 2 week time point.

CONCLUSION

The repair effects of chitin conduit bridging peripheral nerve with small gap (5 mm) are better than that of epineurium suture directly, and possess the potential to substitute the epineurium suture.

Для цитирования: Zhang Pei-xun, Jiang Bao-guo, Zhao Fu-qiang, Fu Zhong-guo, Zhang Dian-ying, Du Chan, Zhang Hong-bo. [Chitin biological tube bridging the peripheral nerve with a small gap].. Zhonghua wai ke za zhi [Chinese journal of surgery]. 2005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.