DOI 10.3109/01676830.2011.648800
The use of mersilene mesh for wrapping of hydroxyapatite orbital implants: mid-term result.
Аннотация
PURPOSE: To report the results of Mersilene mesh wrapped hydroxyapatite orbital implantation.
MATERIALS AND
METHODS
Records of 63 patients operated between April 2002 and March 2006 were retrospectively reviewed. Parameters studied included sex, cause of enucleation, length of follow-up after operation, implant exposure, secondary implantation, and surgeon experience. Student's t-test and χ(2) were used for comparison group having implant exposure and those without implant exposure.
RESULTS
The rate of exposure with use of Mersilene mesh was found to be 4.7%. Gender and cause of enucleation did not influence incidence of implant exposure in this study. The surgeon related factor, reported in terms of oculoplasty surgeon and non-oculoplasty surgeon, was a statistically significant factors that affected implant exposure.
CONCLUSION
Mersilene showed favorable results in wrapping of hydroxyapatite orbital implants.