MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/jpsu.2001.20034

Медицинская библиотека · Journal of pediatric surgery · 2001

Fetal tissue engineering: diaphragmatic replacement.

Fauza D O, Marler J J, Koka R, Forse R A, Mayer J E, Vacanti J P

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND/PURPOSE: Prosthetic repair of congenital diaphragmatic hernia has been associated with high complication rates. This study was aimed at applying fetal tissue engineering to diaphragmatic replacement.

METHODS

Fetal lambs underwent harvest of skeletal muscle specimens. Once expanded in vitro, fetal myoblasts were suspended in a collagen hydrogel submitted to controlled radial tension. The construct was then placed in a bioreactor. After birth, all animals underwent creation of 2 diaphragmatic defects. One defect was repaired with the autologous-engineered construct placed in between 2 acellular supporting membranes and the other with an identical construct but without any cells. Each animal was its own control (graft, n = 10). Animals were killed at different time-points postimplantation for histologic examination. Statistical analysis was by analysis of variance (ANOVA).

RESULTS

Fetal myoblasts expanded up to twice as fast as neonatal cells. Hydrogel-based radial tension enhanced construct architecture by eliciting cell organization within the scaffold. No eventration was present in 4 of 5 engineered constructs but in 0 of 5 acellular grafts (P<.05). At harvest, engineered constructs were thick and histologically resembled normal skeletal muscle, whereas acellular grafts were thin, floppy, and showed low cell density with increased fibrosis.

CONCLUSIONS

Unlike acellular grafts, engineered cellular diaphragmatic constructs are anatomically and histologically similar to normal muscle. Fetal tissue engineering may be a viable alternative for diaphragmatic replacement.

Для цитирования: Fauza D O, Marler J J, Koka R, Forse R A, Mayer J E, Vacanti J P. Fetal tissue engineering: diaphragmatic replacement.. Journal of pediatric surgery. 2001. DOI: 10.1053/jpsu.2001.20034.