MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0885328214537858

Медицинская библиотека · Journal of biomaterials applications · 2014

Assessing cement injection behaviour in cancellous bone: an in vitro study using flow models.

Bou-Francis Antony, López Alejandro, Persson Cecilia, Hall Richard M, Kapur Nikil

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Understanding the cement injection behaviour during vertebroplasty and accurately predicting the cement placement within the vertebral body is extremely challenging. As there is no standardized methodology, we propose a novel method using reproducible and pathologically representative flow models to study the influence of cement properties on injection behaviour. The models, confined between an upper glass window and a lower aluminium plate, were filled with bone marrow substitute and then injected (4, 6 and 8 min after cement mixing) with commercially available bone cements (SimplexP, Opacity+, OsteopalV and Parallax) at a constant flow rate (3 mL/min). A load cell was used to measure the force applied on the syringe plunger and calculate the peak pressure. A camera was used to monitor the cement flow during injection and calculate the following parameters when the cement had reached the boundary of the models: the time to reach the boundary, the filled area and the roundness. The peak pressure was comparable to that reported during clinical vertebroplasty and showed a similar increase with injection time. The study highlighted the influence of cement formulations and model structure on the injection behaviour and showed that cements with similar composition/particle size had similar flow behaviour, while the introduction of defects reduced the time to reach the boundary, the filled area and the roundness. The proposed method provides a novel tool for quick, robust differentiation between various cement formulations through the visualization and quantitative analysis of the cement spreading at various time intervals.

Для цитирования: Bou-Francis Antony, López Alejandro, Persson Cecilia, Hall Richard M, Kapur Nikil. Assessing cement injection behaviour in cancellous bone: an in vitro study using flow models.. Journal of biomaterials applications. 2014. DOI: 10.1177/0885328214537858.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.