Cough ability measurements and recurrent respiratory symptoms in individuals with Ataxia Telangiectasia.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Vilozni Daphna, Lavie Moran, Sarouk Ifat, Levi Yonit, Alcaneses Ofek Mary-Rose, Efrati Ori

Аннотация

OBJECTIVES: Ataxia-Telangiectasia (A-T) individuals often present with respiratory muscle weakness, causing recurrent respiratory system infections, asthma-like symptoms, and chronic cough life-threatening events. The cough flow volume maneuver may reveal powerless airflow needed for efficient cough. The study aims to explore cough ability in relation to the flow/volume maneuver.

METHODS: Data collected retrospectively from clinical charts of 35 A-T patients (age 12.7 ± 4.9 years) included forced expiratory and cough flow/volume maneuvers performed on the same day. Analysis compared among the maneuvers matching indices, numbers of cough-spikes, flow rate decay, and the reference data of similar ages. Adjusted to age, BMI, and number of hospitalizations prior to the tests, values were correlated with the cough indices.

RESULTS: Cough peak-flow (C-PF) was propagated within 90 ± 20 ms compared with peak expiratory flow (PEF > 200 ms). C-PF measured values were higher than expiratory peak-flow measured values (3.27 ± 1.53 L/s versus 3.02 ± 1.52 L/s, respectively, but C-PF (%predicted) values were significantly lower than expiratory peak-flow (%predicted) (46 ± 15 versus 68 ± 20 %predicted, respectively, p < 0.002). The number of spikes/maneuver was low when compared with reference (2.0 ± 0.8 versus 6-12 spikes) and cough vital-capacity was lower than expiratory vital capacity (0.95 ± 0.43 versus 1.03 ± 0.47; p < 0.01). Inefficient C-PF was more prevalent in patients suffering from recurrent respiratory illness. The length of wheelchair confinement duration mostly influenced the C-VC level.

CONCLUSIONS: The cough flow-volume curve can be applied as a method to follow cough ability in patients with A-T who showed a significantly reduced cough capacity. Further studies are needed to establish if the findings may aid decisions regarding cough assistance.