DOI 10.1017/s1047951110001733

Медицинская библиотека · Cardiology in the young · 2010

Microembolic signals measured by transcranial Doppler during transcatheter closure of atrial septal defect using the Amplatzer septal occluder.

Itoh Shinich, Suda Kenji, Kishimoto Shintaro, Nishino Hiroshi, Kudo Yoshiyuki, Iemura Motofumi, Teramachi Yozo, Matsuishi Toyojiro, Yasunaga Hiroshi

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To determine the frequency and factors associated with increase in microembolic signals during transcatheter closure of atrial septal defect using the Amplatzer septal occluder.

METHODS

During the procedure in 16 patients, we measured microembolic signals using transcranial Doppler. Procedure time was divided into five periods: right cardiac catheterisation; left cardiac catheterisation; left cardiac angiocardiography; sizing and long sheath placement; device placement and release. We compared numbers of microembolic signals among the five periods and identified factors associated with them.

RESULTS

Mean size of septal occluder was 16 millimetres in diameter. Total number of microembolic signals was a median of 31.5, ranging from 3 to 113. Microembolic signals in three periods, left cardiac catheterisation; sizing, and long sheath placement; and device placement and release, were not significantly different from one another, but were significantly higher than those in the remaining two periods, right cardiac catheterisation and left cardiac angiocardiography (median was 9 in left cardiac catheterisation; 6 in sizing and long sheath placement; 6.5 in device placement and release, versus 0 in right cardiac catheterisation and 1 in left cardiac angiocardiography, p less than 0.05, respectively). Importantly, the time for device manipulation positively correlated with total number of microembolic signals (r equals 0.77, p less than 0.001), although fluoroscopic time, age, or size of septal occluder did not.

CONCLUSIONS

Transcatheter closure of atrial septal defect using the Amplatzer septal occluder produces microemboli, especially during device placement. To minimise the risk of systemic embolism, we must decrease the time for device manipulation.

Для цитирования: Itoh Shinich, Suda Kenji, Kishimoto Shintaro, Nishino Hiroshi, Kudo Yoshiyuki, Iemura Motofumi, Teramachi Yozo, Matsuishi Toyojiro, Yasunaga Hiroshi. Microembolic signals measured by transcranial Doppler during transcatheter closure of atrial septal defect using the Amplatzer septal occluder.. Cardiology in the young. 2010. DOI: 10.1017/s1047951110001733.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.