MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2009.02.031

Медицинская библиотека · Biosensors & bioelectronics · 2009

Development of redox-labeled electrochemical immunoassay for polycyclic aromatic hydrocarbons with controlled surface modification and catalytic voltammetric detection.

Wei Ming-Yuan, Wen Shou-Dong, Yang Xi-Qiang, Guo Liang-Hong

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

A redox-labeled direct competitive electrochemical immunoassay for polycyclic aromatic hydrocarbons (PAHs) was developed. A ruthenium tris(bipyridine)-pyrenebutyric acid conjugate was synthesized as the redox-labeled tracer. Its recognition by an anti-PAH monoclonal antibody was confirmed by surface plasmon resonance. In the immunoassay, the antibody was immobilized on (3-glycidoxypropyl)-trimethoxysilane (GPTMS)-modified indium tin oxide (ITO) electrodes. The assay was quantified by measuring the electro-catalytic current of the redox label in an oxalate-containing electrolyte which served as a sacrificial electron donor to amplify the current signal. Formation of GPTMS film on ITO and subsequent antibody immobilization were characterized by X-ray photoelectron spectroscopy (XPS) and electrochemistry. Using a ruthenium tris(bipyridine)-conjugated IgG (IgG-Ru) as the surface-bound redox probe, the highest electrochemical signal was obtained on GPTMS electrodes with 1 h modification. Under the optimized conditions for ITO modification, antibody immobilization and tracer concentration, competition curves for benzo[a]pyrene and pyrenebutyric acid were obtained with a detection limit of 2.4 and 10 ng mL(-1), respectively. The redox-labeled electrochemical immunoassay with signal amplification mechanism offers a potential analytical method for the simultaneous detection of multiple environmental organic pollutants on antibody biochips.

Для цитирования: Wei Ming-Yuan, Wen Shou-Dong, Yang Xi-Qiang, Guo Liang-Hong. Development of redox-labeled electrochemical immunoassay for polycyclic aromatic hydrocarbons with controlled surface modification and catalytic voltammetric detection.. Biosensors & bioelectronics. 2009. DOI: 10.1016/j.bios.2009.02.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.