MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1752-7163/aaaf24

Медицинская библиотека · Journal of breath research · 2018

Evaluation of a new simple collection device for sampling of microparticles in exhaled breath.

Seferaj Sabina, Ullah Shahid, Tinglev Åsa, Carlsson Sten, Winberg Jesper, Stambeck Peter, Beck Olof

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

The microparticle fraction of exhaled breath is of interest for developing clinical biomarkers. Exhaled particles may contain non-volatile components from all parts of the airway system, formed during normal breathing. This study aimed to evaluate a new, simple sampling device, based on impaction, for collecting microparticles from exhaled breath. Performance of the new device was compared with that of the existing SensAbues membrane filter device. The analytical work used liquid chromatography-tandem mass spectrometry methods. The new device collected three subsamples and these were separately analysed from eight individuals. No difference was observed between the centre position (0.91 ng/sample) and the side positions (1.01 ng/sample) using major phosphatidylcholine (PC) 16:0/16:0 as the analyte. Exhaled breath was collected from eight patients on methadone maintenance treatment. The intra-individual variability in measured methadone concentration between the three collectors was 8.7%. In another experiment using patients on methadone maintenance treatment, the sampling efficiency was compared with an established filter device. Compared to the existing device, the efficiency of the new device was 121% greater for methadone and 1450% greater for DPPC. The data from lipid analysis also indicated that a larger fraction of the collected material was from the distal parts. Finally, a study using an optical particle counter indicated that the device preferentially collects the larger particle fraction. In conclusion, this study demonstrates the usefulness of the new device for collecting non-volatile components from exhaled breath. The performance of the device was superior to the filter device in several aspects.

Для цитирования: Seferaj Sabina, Ullah Shahid, Tinglev Åsa, Carlsson Sten, Winberg Jesper, Stambeck Peter, Beck Olof. Evaluation of a new simple collection device for sampling of microparticles in exhaled breath.. Journal of breath research. 2018. DOI: 10.1088/1752-7163/aaaf24.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.