MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/prs.0b013e318221dc3e

Медицинская библиотека · Plastic and reconstructive surgery · 2011

Reliable harvesting of a large thoracodorsal artery perforator flap with emphasis on perforator number and spacing.

Hwang Jin Hee, Lim So-Young, Pyon Jai-Kyong, Bang Sa-Ik, Oh Kap-Sung, Mun Goo-Hyun

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Thoracodorsal artery perforator flaps are useful for covering extensive defects because of their generous donor-site dimensions. However, large flaps increase the risk of partial flap necrosis, and a reliable means of sizing thoracodorsal artery perforator flaps has not been devised. The authors reviewed a series of large thoracodorsal artery perforator flap transfers performed under various reconstructive conditions to evaluate surgical outcomes and placed emphasis on flap design and harvesting technique.

METHODS

A consecutive series of large thoracodorsal artery perforator flaps (>20 cm long) performed between November of 2005 and March of 2010 were included in this study. Patient charts, operative records, and photographs were reviewed.

RESULTS

A total of 20 flaps with an average size of 25 × 11 cm in 20 patients were identified; the largest flap measured 32 × 13 cm. The average number of perforators included was 2.6 per flap (range, one to four). Four different harvesting techniques were used, depending on perforator numbers and locations. All large flaps survived without sizable partial flap necrosis. Complications included wound dehiscence in one donor and two recipient sites; all healed after wound repair. Tip necrosis of a small area developed but healed with conservative wound care.

CONCLUSIONS

This study reports the clinical safety of large thoracodorsal artery perforator flaps with customized thickness control, which can be reliably harvested beyond 20 cm in length by carefully considering perforator numbers and locations. To optimize tissue perfusion in these large flaps, effort is required to capture multiple perforators from various sources and to obtain an ideal arrangement.

CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.

Для цитирования: Hwang Jin Hee, Lim So-Young, Pyon Jai-Kyong, Bang Sa-Ik, Oh Kap-Sung, Mun Goo-Hyun. Reliable harvesting of a large thoracodorsal artery perforator flap with emphasis on perforator number and spacing.. Plastic and reconstructive surgery. 2011. DOI: 10.1097/prs.0b013e318221dc3e.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.