MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10096-025-05316-0

Медицинская библиотека · European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology · 2025

Optimizing filamentous fungi identification by MALDI-TOF MS: A comparative analysis of key factors.

Dogan Özlem, Ozmen-Capin Busra Betul, White John, Serra Chiara, Ahmed Sultan, Botero-Kleiven Silvia, Özenci Volkan

СтатьяСравнительное исследованиеОценочное исследованиеПеревод в очереди

Аннотация

PURPOSE: The identification of filamentous fungi in clinical microbiology laboratories remains a challenging task. Although matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) has revolutionized microbial diagnostics by enabling rapid and accurate species-level identification, its application to molds is still evolving. This study aims to evaluate the performance of two Bruker MALDI-TOF MS systems, Sirius One and Microflex 3.1, for the identification of filamentous fungi using different extraction protocols and database configurations.

METHOD: A total of 68 filamentous fungal isolates, including clinically significant species, were analyzed. Fungal cultures were processed under standardized conditions using two protein extraction methods: a detailed in-tube extraction with ethanol, formic acid, and acetonitrile, and a direct on-plate extraction. Spectra were acquired using both Sirius One and Microflex 3.1 systems, and identifications were performed using manufacturer-provided databases and the MSI-2.0 database.

RESULTS

The Sirius One system outperformed Microflex 3.1, achieving a 92.6% correct identification rate with the MSI-2 database compared to 70.6% for Microflex (p < 0.01). When using manufacturer-provided databases, identification rates were lower: 51.5% for Sirius One and 41.2% for Microflex. Notably, the on-plate extraction method performed comparably to the in-tube method, achieving 94.1% accuracy with Sirius One and the MSI-2 database.

CONCLUSION

The combination of the Sirius One system, MSI-2.0 database, and on-plate extraction method provides a highly effective and time-efficient workflow for the identification of filamentous fungi in routine clinical diagnostics, reaching 94.1% accuracy. This approach is recommended for implementation in clinical mycology laboratories, though further optimization of manufacturer-supplied databases remains necessary.

Для цитирования: Dogan Özlem, Ozmen-Capin Busra Betul, White John, Serra Chiara, Ahmed Sultan, Botero-Kleiven Silvia, Özenci Volkan. Optimizing filamentous fungi identification by MALDI-TOF MS: A comparative analysis of key factors.. European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology. 2025. DOI: 10.1007/s10096-025-05316-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.