Brain contrasting ability of blood-brain-barrier-permeable nitroxyl contrast agents for magnetic resonance redox imaging.

Matsumoto Ken-Ichiro, Yamasaki Toshihide, Nakamura Mizuki, Ishikawa Junji, Ueno Megumi, Nakanishi Ikuo, Sekita Aiko, Ozawa Yoshikazu, Kamada Tadashi, Aoki Ichio, Yamada Ken-Ichi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: The detailed in vivo T1 -weighted contrasting abilities of nitroxyl contrast agents, which have been used as redox responsive contrast agents in several magnetic resonance-based imaging modalities, in mouse brain were investigated.

METHODS

Distribution and pharmacokinetics of five types of five-membered-ring nitroxyl radical compound were compared using T1 -weighted MRI.

RESULTS

The blood-brain barrier (BBB) -impermeable 3-carboxy-2,2,5,5-tetramethylpyrrolidine-N-oxyl (CxP) could not be distributed in the brain. The slightly lipophilic 3-carbamoyl-2,2,5,5-tetramethylpyrrolidine-N-oxyl (CmP) showed slight distribution only in the ventricle, but not in the medulla and cortex. The amphiphilic 3-methoxy-carbonyl-2,2,5,5-tetramethyl-pyrrolidine-N-oxyl (MCP) had good initial uniform distribution in the brain and showed typical 2-phase signal decay profiles. A brain-seeking nitroxyl probe, acetoxymethyl-2,2,5,5-tetramethyl-pyrrolidine-N-oxyl-3-carboxylate (CxP-AM), showed an accumulating phase, and then its accumulation was maintained in the medulla and ventricle regions, but not in the cortex. The lipophilic 4-(N-methyl piperidine)-2,2,5,5-tetramethylpyrroline-N-oxyl (23c) was well distributed in the cortex and medulla, but slightly in the ventricle, and showed relatively rapid linear signal decay.

CONCLUSION

Nitroxyl contrast agents equipped with a suitable lipophilic substitution group could be BBB-permeable functional contrast agents. MR redox imaging, which can estimate not only the redox characteristics but also the detailed distribution of the contrast agents, is a good candidate for a theranostic tool. Magn Reson Med 76:935-945, 2016. © 2015 Wiley Periodicals, Inc.

Для цитирования: Matsumoto Ken-Ichiro, Yamasaki Toshihide, Nakamura Mizuki, Ishikawa Junji, Ueno Megumi, Nakanishi Ikuo, Sekita Aiko, Ozawa Yoshikazu, Kamada Tadashi, Aoki Ichio, Yamada Ken-Ichi. Brain contrasting ability of blood-brain-barrier-permeable nitroxyl contrast agents for magnetic resonance redox imaging.. Magnetic resonance in medicine. 2015. DOI: 10.1002/mrm.25918.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.