Heating Intravenous Fluid Tubing in an Experimental Setting for Prehospital Hypothermia.
Аннотация
OBJECTIVE
Hypothermia secondary to environmental exposure is a serious condition. Active external warming measures to treat it may prove challenging in the prehospital setting. We conducted an experimental study to measure the ability of commercially available heating elements to warm intravenous (IV) fluids during infusion.
METHODS
250-milliliter bags of dextrose 10% solution were suspended inside a refrigerator. IV tubing was coiled, and the tubing output was placed inside a thermally insulated cup. The tubing was heated directly with a hand warmer, a meals ready-to-eat heater, or a heating blanket. Fluids were run through the IV line. The temperature of the fluid at the tubing output was measured. The initial and final infusion temperatures for the methods were compared.
RESULTS
The use of hand warmers, meals ready-to-eat heaters, and heating blankets to warm IV tubing did increase the temperature of the fluids but was ineffective at achieving the desired mean infusion temperature of 35°C to 42°C.
CONCLUSION
Although the mean temperature increase did not meet the established experimental threshold, further research is needed to determine whether the fluid warming effect of these commercial heating elements used in the prehospital environment is significant enough to limit heat loss while repleting the dextrose of a hypothermic, hypoglycemic patient.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.