MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The European journal of prosthodontics and restorative dentistry · 2004

The effect of a range of disinfectants on the dimensional accuracy of some impression materials.

Jagger D C, Al Jabra O, Harrison A, Vowles R W, McNally L

СтатьяПеревод в очереди

Аннотация

In this study the dimensional accuracy of two model materials; dental stone and plaster of Paris, reproduced from three commonly used impression materials; alginate, polyether and addition-cured silicone, retained by their adhesives in acrylic resin trays and exposed to four disinfectant solutions was evaluated. Ninety casts were used to investigate the effect of the four disinfectants on the dimensional accuracy of alginate, polyether and addition-cured silicone impression material. For each impression material 30 impressions were taken, half were poured in dental stone and half in plaster of Paris. The disinfectants used were Dimenol, Perform-ID, MD-520, and Haz-tabs. Measurements were carried out using a High Precision Reflex Microscope. For the alginate impressions only those disinfected by 5-minute immersion in Haz-tabs solution and in full-strength MD 520 were not adversely affected by the disinfection treatment. All polyether impressions subjected to immersion disinfection exhibited a clinically acceptable expansion. Disinfected addition-cured silicone impressions produced very accurate stone casts. Those disinfected by spraying with fill-strength Dimenol produced casts that were very similar to those left as controls, but those treated by immersion disinfection exhibited negligible and clinically acceptable expansion. The results of the studied demonstrated that the various disinfection treatments had different effects on the impression materials. It is important that an appropriate disinfectant is used for each type of impression material.

Для цитирования: Jagger D C, Al Jabra O, Harrison A, Vowles R W, McNally L. The effect of a range of disinfectants on the dimensional accuracy of some impression materials.. The European journal of prosthodontics and restorative dentistry. 2004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.