BACKGROUND

Patient radiation exposure associated with the use of computed tomography (CT) navigation during spinal surgeries was widely compared with other intraoperative imaging techniques. The aim of this study is to explore the use of navigation with regard to current spinal surgery practices and the technical limitations of such imaging systems.

METHODS

Dosimetric data from 101 patients who underwent intraoperative, CT-navigated spine surgery were retrospectively collected. The study population was divided into 3 groups according to the primary surgical indication. The number of CT image acquisitions per patient, the field length, and the time of exposure per acquisition during a single surgery were compared as well as the radiation dose emitted to patients.

RESULTS

Dose-length products (DLP) per acquisition were 678.52, 656.8, and 649.36 mGy·cm with no significant difference for spinal deformity (SD), degenerative disease (DD), and vertebral fracture (VF) procedures, respectively. Analyzing the number of CT image acquisitions per patient revealed that repeated intraoperative scans were often performed for patients who were suffering from an SD due to technical limitations of the navigation. As a consequence, the cumulative dose was higher in the SD group (DLP total = 1175 mGy·cm) than in the DD (DLP total = 762.74 mGy·cm) and VF (DLP total = 649.36 mGy·cm) groups.

CONCLUSIONS

CT navigation is an efficient intraoperative imaging technique that reduces the rate of surgical complications, but its technical limitations lead to an increased risk of patient radiation exposure, especially for complex surgeries where multiple scanning acquisitions are needed.

CLINICAL RELEVANCE: To avoid patient's overexposure, spine surgeons should minimize the number of intraoperative acquisitions while considering the complexity of the surgery and the limitations of the guidance system. The use of dual guidance systems has also to be considered according to the benefit-risk balance between patient's outcomes and radiation dose exposure.

Для цитирования: Soratto Heitich Ferrazza Magda Helena, Delwing-Dal Magro Débora, Salamaia Eloise, Guareschi Thales Ercole, Fernandes Erzinger Luis Felipe, Maia Thayná Patachini, Siebert Cassiana, Dos Santos Tiago Marcon, de Souza Wyse Angela Terezinha, Borgmann Gabriela, Plautz Katherine, Delwing-de Lima Daniela. Sub‑chronic administration of lead alters markers of oxidative stress, acetylcholinesterase and Na+K+‑ATPase activities in rat brain.. Acta neurobiologiae experimentalis. 2023. DOI: 10.55782/ane-2023-019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.