MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euq050

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2010

Wolff-Parkinson-White ablation after a prior failure: a 7-year multicentre experience.

Sacher Frederic, Wright Matthew, Tedrow Usha B, O'Neill Mark D, Jais Pierre, Hocini Mélèze, Macdonald Rosie, Davies D Wyn, Kanagaratnam Prapa, Derval Nicolas, Epstein Laurence, Peters Nicholas S, Stevenson William G, Haissaguerre Michel

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIMS: Catheter ablation for Wolff-Parkinson-White syndrome (WPW) can be challenging and is associated with failure in approximately 1-5% of cases. We analysed the reasons for failure.

METHODS AND

RESULTS

All patients (89 patients, 28 +/- 16 years old) referred for WPW ablation after a prior failure were studied. Reasons for the prior failure as well as for the acute success were analysed. The repeat procedure was successful in 81 (91%) patients. Multiple (2.7 +/- 0.9) or large accessory pathways (APs) were seen in 13 patients. For left lateral APs, inaccurate mapping and lack of transseptal access during the index procedure accounted for failure (n = 15). An irrigated-tip catheter was required for epicardial APs (n = 7). In addition, seven posteroseptal APs required bi-atrial and coronary sinus (CS) applications in order to succeed. For parahisian and midseptal APs, radiofrequency was cautiously titrated from 5 to 30 W, eliminating the AP in three patients. Cryoablation was used in seven patients (acute success in six but delayed recurrences in three of these). For patients with CS AP, irrigated ablation in the CS was crucial to deliver adequate power. For anteroseptal and right lateral APs, a successful outcome was achieved with long sheaths (n = 5) or a left subclavian approach (anteroseptal, n = 4).

CONCLUSION

Failure in WPW ablation may be due to a variety of reasons but catheter manipulation and inaccurate mapping remain the two major causes. Knowledge of the reasons for failure depending on the location of the WPW may facilitate a successful outcome.

Для цитирования: Sacher Frederic, Wright Matthew, Tedrow Usha B, O'Neill Mark D, Jais Pierre, Hocini Mélèze, Macdonald Rosie, Davies D Wyn, Kanagaratnam Prapa, Derval Nicolas, Epstein Laurence, Peters Nicholas S, Stevenson William G, Haissaguerre Michel. Wolff-Parkinson-White ablation after a prior failure: a 7-year multicentre experience.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2010. DOI: 10.1093/europace/euq050.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.