MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/eun380

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2009

Single-centre use of implantable loop recorders in patients with congenital heart disease.

Kenny Damien, Chakrabarti Shanta, Ranasinghe Aruna, Chambers Amy, Martin Robin, Stuart Graham

СтатьяПеревод в очереди

Аннотация

AIMS: To determine the efficacy of the implantable loop recorder (ILR) in patients with congenital heart disease.

METHODS AND

RESULTS

Retrospective data analyses of all patients with congenital heart disease undergoing ILR implantation in a congenital cardiac centre. Of 78 ILRs implanted between July 2000 and October 2007, 22 (15 male) patients had congenital heart disease. The median age at implantation was 15.5 years (7.0-46.5). Six patients had neurodevelopmental delay. Indications for implantation were syncope (n = 15), palpitations (n = 4), and pre-syncope (n = 3). Median implantation time was 19 months (1-30). Explantation data were available in 16 patients (73%). Implantable loop recorders were explanted following establishment of positive diagnosis (n = 3), negative diagnosis (n = 7), and at the end of battery life (n = 4). One patient died with the ILR in situ. One device eroded after 2 months without further complication. Following ILR interrogation, diagnosed arrhythmias included ventricular tachycardia (n = 2) and sinus node dysfunction (n = 1). On the basis of these findings, two patients had intracardiac defibrillators and one patient had a dual-chamber pacemaker implanted.

CONCLUSION

Implantable loop recorders lead to a positive or negative arrhythmic diagnosis following explantation in 71% of patients with congenital heart disease. This is particularly beneficial in patients with neurodevelopmental delay where accurate history is often limited.

Для цитирования: Kenny Damien, Chakrabarti Shanta, Ranasinghe Aruna, Chambers Amy, Martin Robin, Stuart Graham. Single-centre use of implantable loop recorders in patients with congenital heart disease.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2009. DOI: 10.1093/europace/eun380.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.