Estimation of children's radiation dose from cardiac catheterisations, performed for the diagnosis or the treatment of a congenital heart disease using TLD dosimetry and Monte Carlo simulation.

Yakoumakis E N, Gialousis G I, Papadopoulou Despina, Makri Triantafillia, Pappouli Zografia, Yakoumakis Nikolaos, Papagiannis Panayotis, Georgiou Evangelos

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

Entrance surface radiation doses were measured with thermoluminescent dosimeters for 98 children who were referred to a cardiology department for the diagnosis or the treatment of a congenital heart disease. Additionally, all the radiographic parameters were recorded and Monte Carlo simulations were performed for the estimation of entrance surface dose to effective dose conversion factors, in order to further calculate the effective dose for each child. For diagnostic catheterisations the values ranged from 0.16 to 14.44 mSv, with average 3.71 mSv, and for therapeutic catheterisations the values ranged from 0.38 to 25.01 mSv, with average value 5 mSv. Effective doses were estimated for diagnostic procedures and interventional procedures performed for the treatment of five different heart diseases: (a) atrial septal defect (ASD), (b) ventricular septal defect (VSD), (c) patent ductus arteriosus (PDA), (d) aorta coarctation and (e) pulmonary stenosis. The high levels of radiation exposure are, however, balanced with the advantages of cardiac catheterisations such as the avoidance of surgical closure and the necessity of shorter or even no hospitalisation.

Для цитирования: Yakoumakis E N, Gialousis G I, Papadopoulou Despina, Makri Triantafillia, Pappouli Zografia, Yakoumakis Nikolaos, Papagiannis Panayotis, Georgiou Evangelos. Estimation of children's radiation dose from cardiac catheterisations, performed for the diagnosis or the treatment of a congenital heart disease using TLD dosimetry and Monte Carlo simulation.. Journal of radiological protection : official journal of the Society for Radiological Protection. 2009. DOI: 10.1088/0952-4746/29/2/011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.