MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.2c01083

Медицинская библиотека · Analytical chemistry · 2022

Glow and Flash Adjustable Chemiluminescence with Tunable Waveband from the Same CuInS2@ZnS Nanocrystal Luminophore.

Dong Shuangtian, Wang Dongyang, Gao Xuwen, Fu Li, Jia Jingna, Xu Yuqi, Zhang Bin, Zou Guizheng

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

All commercial chemiluminescence (CL) assays are conducted with either glow or flash CL of eye-visible waveband from chemical luminophores. Herein, glow and flash, as well as waveband adjustable CL from the same nanoparticle luminophore of thiol-capped CuInS2@ZnS nanocrystals (CIS@ZnS-Thiol), are proposed via extensively exploiting the differed redox nature of CL triggering reagents. Taking thiosalicylic acid (TSA) as the model thiol-capping agent, the electron-injection-initiated charge transfer between CIS@ZnS-TSA and reductant can bring out efficient glow CL while the hole-injection-initiated charge transfer between CIS@ZnS-TSA and oxidant can give off obvious flash CL under optimum conditions. The maximum emission wavelength for CL of CIS@ZnS-TSA is adjustable from 730 nm to 823 nm via employing different triggering agents. Promisingly, the coexistent reductant of N2H4·H2O and oxidant of H2O2 can be employed as dual triggering reagents to trigger eye-visible and highly efficient flash CL from CIS@ZnS-TSA. The maximum emission intensity for flash CL of CIS@ZnS-TSA/N2H4-H2O2 is 101-fold greater than the glow CL of CIS@ZnS-TSA/N2H4 and 22-fold greater than the flash CL of CIS@ZnS-TSA/H2O2, respectively. The flash CL from CIS@ZnS-TSA/N2H4-H2O2 is qualified for highly sensitive and selective CL immunoassay in a commercialized typical procedure with the entire operating process manually terminated within 35 min.

Для цитирования: Dong Shuangtian, Wang Dongyang, Gao Xuwen, Fu Li, Jia Jingna, Xu Yuqi, Zhang Bin, Zou Guizheng. Glow and Flash Adjustable Chemiluminescence with Tunable Waveband from the Same CuInS2@ZnS Nanocrystal Luminophore.. Analytical chemistry. 2022. DOI: 10.1021/acs.analchem.2c01083.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.