MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0894-7317(03)00407-3

Медицинская библиотека · Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2003

A novel Doppler echocardiographic method of measuring the biophysical properties of the aorta in pediatric patients.

Sandor George G S, Hishitani Takashi, Petty Ross E, Potts Mary T, Desouza Astrid, Desouza Eustace, Potts James E

СтатьяПеревод в очереди

Аннотация

BACKGROUND

This study was performed to: (1) assess the feasibility of measuring pulse wave velocity (PWV) from aortic (AO) Doppler flow and deriving AO input and characteristic impedances and the arterial pressure strain elastic modulus; and (2) compare these indices in pediatric patients with arterial disease to control (C) patients.

METHODS

There were 14 healthy children in the C group, 9 with inflammatory connective tissue diseases (ICTD), and 6 with Marfan syndrome (M). Using standard echocardiographic equipment, the AO annulus, AO root diameter in systole (AO(S)) and diastole (AO(D)), and AO length (L) were measured. The time taken for the Doppler signal to travel from the ascending to descending aorta was measured. AO peak flow was calculated from AO annulus cross-sectional area x peak aortic velocity (AoV); PWV = L/time taken for the Doppler signal to travel from the ascending to descending aorta; input impedance = (systolic - diastolic blood pressure)/(AO cross-sectional area x AoV); characteristic impedance = (PWV x rho)/Ao cross-sectional area (where rho = 1.06); and pressure strain elastic modulus = (systolic - diastolic blood pressure)/[(AO(S) - AO(D))/AO(D)]; beta index = ln (systolic/diastolic blood pressure)/[(AO(S) - AO(D))/AO(D)].

RESULTS

Results for PWV were ICTD = M > C (533, 496, 362 cm/s; P <.02); for input impedance were ICTD > M = C (245, 120, 116; P <.03); for characteristic impedance were ICTD < M = C (249, 107, 142; P <.05); for pressure strain elastic modulus were M > ICTD = C (262, 447, 187; P <.003); and for beta index were M > ICTD > C (2.91, 2.51, 2.13; P <.0006).

CONCLUSIONS

This novel, relatively simple method of assessing the biophysical properties of the aorta shows abnormal function in patients with M and ICTD. This technique may be helpful in the long-term follow up of patients with arterial disease.

Для цитирования: Sandor George G S, Hishitani Takashi, Petty Ross E, Potts Mary T, Desouza Astrid, Desouza Eustace, Potts James E. A novel Doppler echocardiographic method of measuring the biophysical properties of the aorta in pediatric patients.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2003. DOI: 10.1016/s0894-7317(03)00407-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.