Characterization of Optimized TiO2 Nanotubes Morphology for Medical Implants: Biological Activity and Corrosion Resistance.

Nogueira Ricardo Pereira, Deuzimar Uchoa Jose, Hilario Fanny, Santana-Melo Gabriela de Fátima, de Vasconcellos Luana Marotta Reis, Marciano Fernanda Roberta, Roche Virginie, Moreira Jorge Junior Alberto, Lobo Anderson Oliveira

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Nanostructured surface modifications of Ti-based biomaterials are moving up from a highly-promising to a successfully-implemented approach to developing safe and reliable implants.

METHODS

The study's main objective is to help consolidate the knowledge and identify the more suitable experimental strategies related to TiO2 nanotubes-modified surfaces. In this sense, it proposes the thorough investigation of two optimized nanotubes morphologies in terms of their biological activity (cell cytotoxicity, alkaline phosphatase activity, alizarin red mineralization test, and cellular adhesion) and their electrochemical behavior in simulated body fluid (SBF) electrolyte. Layers of small-short and large-long nanotubes were prepared and investigated in their amorphous and crystallized states and compared to non-anodized samples.

RESULTS

Results show that much more than the surface area development associated with the nanotubes' growth; it is the heat treatment-induced change from amorphous to crystalline anatase-rutile structures that ensure enhanced biological activity coupled to high corrosion resistance.

CONCLUSION

Compared to both non-anodized and amorphous nanotubes layers, the crystallized nano-structures' outstanding bioactivity was related to the remarkable increase in their hydrophilic behavior, while the enhanced electrochemical stability was ascribed to the thickening of the dense rutile barrier layer at the Ti surface beneath the nanotubes.

Для цитирования: Nogueira Ricardo Pereira, Deuzimar Uchoa Jose, Hilario Fanny, Santana-Melo Gabriela de Fátima, de Vasconcellos Luana Marotta Reis, Marciano Fernanda Roberta, Roche Virginie, Moreira Jorge Junior Alberto, Lobo Anderson Oliveira. Characterization of Optimized TiO2 Nanotubes Morphology for Medical Implants: Biological Activity and Corrosion Resistance.. International journal of nanomedicine. 2021. DOI: 10.2147/ijn.s285805.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.