MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/embc48229.2022.9871344

Медицинская библиотека · Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2022

Improving Patient Comfort in MRI with Predictive Acoustic Noise Cancelling.

Siuryte Paulina, Tourais Joao, Weingartner Sebastian

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

With sound pressure levels reaching up to 130 dB, acoustic noise in Magnetic Resonance Imaging (MRI) is one of the main sources of patient discomfort in otherwise one of the safest medical imaging modalities. In this work, a noise prediction-based approach, termed predictive noise cancelling (PNC), is applied, for the first time, to suppress noise in MRI. In PN C the noise from the scanner gradient coils is predicted based on linear time-invariant models, which relate the individual gradient coil (X, Y and Z) input to the acoustic noise output. A model setup was constructed of a custom speaker box and MRI -compatible microphone to demonstrate live noise reduction. Additional tuning steps, including output channel equalization and clock mismatch correction, were performed to maximize noise reduction. A calibration sequence was designed to determine the model and tuning parameters. Analysis of actual scanner noise shows an upper limit of 21 dB noise reduction with the proposed linear model. For the components of a clinical example sequence, the setup demonstrated in-bore live noise reduction of up to 10 dB (7.01 ± 0.31 dB, 6.42 ± 2.04 dB and 9.28 ± 0.26 dB for X, Y and Z gradient coils respectively) in the presence of system imperfections. Clinical relevance - The results indicate promising noise attenuation without the need to modify scanner hardware or compromises in acquisition speed or quality. This has potential to substantially and cost effectively improve patient comfort in clinical MRI.

Для цитирования: Siuryte Paulina, Tourais Joao, Weingartner Sebastian. Improving Patient Comfort in MRI with Predictive Acoustic Noise Cancelling.. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. 2022. DOI: 10.1109/embc48229.2022.9871344.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.