MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/11297298251325391

Медицинская библиотека · The journal of vascular access · 2025

Efficacy, safety, and complications of manta vascular closure device in VA-ECMO decannulation: A systematic review and meta-analysis.

Nunes-Carvalho Joana, Silva Eduardo, Spath Paolo, Araújo-Andrade Leonardo, Troisi Nicola, Neves João Rocha

СтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

BACKGROUND

VenoArterial (VA)-ExtraCorporeal Membrane Oxygenation (ECMO) decannulation was traditionally performed surgically, often resulting in high rates of periprocedural complications such as surgical site infections, bleeding, and elevated patient mobilization costs. The advent of percutaneous techniques, particularly the MANTA® vascular closure device (MVCD), has significantly reduced these risks by enabling faster and safer decannulation. This study aimed to systematically review the success rates and complications associated with the use of percutaneous closure devices for VA-ECMO decannulation.

OBJECTIVE

Therefore, this systematic review with meta-analysis aims to evaluate the success rates and complications associated with the use of MVCD device for VA-ECMO decannulation.

MATERIALS AND

METHODS

A systematic search was conducted across Pubmed, Web of Science, and Cochrane databases to identify studies evaluating postoperative outcomes in patients undergoing VA-ECMO decannulation using the MANTA® vascular closure device. The MANTA® efficacy, incidence of emergent open repair, arterial thrombosis, acute limb ischemia, pseudoaneurysms, and major bleeding were pooled by fixed-effects meta-analysis, with sources of heterogeneity being explored by meta-regression. Assessment of studies' quality was performed using the National Heart, Lung, and Blood Institute (NHLBI) Study Quality Assessment Tool for observational cohorts and case-series studies.

RESULTS

Seven observational studies with 235 patients were included in the final analysis. Overall efficacy of MVCD in VA-ECMO decannulation was 94.8% (95% CI 91.8%-97.9%). In 235 patients, the incidence of emergency open repair after MVCD failure was 3.7% (95% CI 1.3%-6.1%), the incidence of arterial thrombosis was 7.1% (95% CI 2.9%-11.3%), the incidence of pseudoaneurysms was 3.2% (95% CI 0.9%-5.5%), the incidence of acute limb ischemia was 5.0% (95% CI 2.3%-7.8%), and the incidence of major arterial bleeding was 4.1% (95% CI 1.6%-6.7%).

CONCLUSION

This systematic review and meta-analysis highlights the safety and efficacy of the MANTA® vascular closure device in achieving hemostasis following VA-ECMO decannulation, demonstrating an acceptable success rate and a low incidence of major complications. Further studies with larger cohorts are necessary to validate these findings and to address the limitations of this preliminary experience.

Для цитирования: Nunes-Carvalho Joana, Silva Eduardo, Spath Paolo, Araújo-Andrade Leonardo, Troisi Nicola, Neves João Rocha. Efficacy, safety, and complications of manta vascular closure device in VA-ECMO decannulation: A systematic review and meta-analysis.. The journal of vascular access. 2025. DOI: 10.1177/11297298251325391.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.