MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3760/cma.j.issn.0253-3766.2013.03.007

Медицинская библиотека · Zhonghua zhong liu za zhi [Chinese journal of oncology] · 2013

[Correlation of blood flow assessed by CT perfusion imaging and microvascular ultrastructure in non-small cell lung cancer: a preliminary study].

Zhou Hui, Liu Jin-kang, Chen Sheng-xi, Xiong Zeng, Lin Guo-qiang, Zhou Mo-ling, Chen Wei, Lü Hui

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To investigate the correlation between blood flow assessed by CT perfusion imaging and characteristics of microvascular ultrastructure in non-small cell lung cancer (NSCLC).

METHODS

twenty-eight patients with non-small cell lung cancer proven surgically and pathologically underwent perfusion CT examination. The patients were divided into a hyper-perfusion group and a hypo-perfusion group by the median value of blood flow, and then the differences of microvascular ultrastructure in the two groups were analyzed.

RESULTS

The median BF value of the 28 patients was 36.40 ml×100 g(-1)×min(-1). Take this median value as the boundary, the group with hypo-perfusion showed a significantly lower BF value than the group with hyper-perfusion [(30.84 ± 4.79) ml×100 g(-1)×min(-1) vs. (49.67 ± 10.89) ml×100 g(-1)×min(-1), t = -5.925, P < 0.001]. The group with lymph node metastasis showed a significantly lower BF value than the group without lymph node metastasis [(30.78 ± 5.24) ml×100 g(-1)×min(-1) vs. (50.73 ± 11.16) ml×100 g(-1)×min(-1), t = 3.490, P = 0.015]. The maturity of microvessels of the hyper-perfusion group was higher than that of the hypo-perfusion group. Under the electron microscope, the microvessels in the hypo-perfusion group showed a more narrow lumen, poorer integrity of basement membrane, a more close relationship between cancer cells and microvascular wall, and cancer cells were more easily seen in the microvascular lumen.

CONCLUSION

The blood flow value of CT perfusion imaging may be related with the abnormal microvascular ultrastructure, and may be helpful to the prediction of metastasis risk in NSCLC.

Для цитирования: Zhou Hui, Liu Jin-kang, Chen Sheng-xi, Xiong Zeng, Lin Guo-qiang, Zhou Mo-ling, Chen Wei, Lü Hui. [Correlation of blood flow assessed by CT perfusion imaging and microvascular ultrastructure in non-small cell lung cancer: a preliminary study].. Zhonghua zhong liu za zhi [Chinese journal of oncology]. 2013. DOI: 10.3760/cma.j.issn.0253-3766.2013.03.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.