Clinical outcomes and survival rate of cementless modular distal fixation femoral stem for revision hip arthroplasty: A minimum 6-year follow-up.

Kang Joon Soon, Na Yeop, Ko Bong Seong, Jeon Yoon Sang

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Revision hip arthroplasty is a very challenging procedure. Use of a modular distal fixation stem is one of the available options for revision arthroplasty in patients with proximal femoral bone deficiency. The purpose of this study was to evaluate mid- to long-term outcomes of cementless modular distal fixation femoral stem implantation in revision hip surgery.

METHODS

Clinical and radiological findings, complications, and stem survival rate were analyzed for 46 patients (48 hips) who underwent revision hip arthroplasty using a cementless modular distal fixation femoral stem. The mean patient age was 58.8 years (range 31-82 years) and the mean follow-up period was 95 months (72-122 months). The preoperative diagnoses were aseptic loosening (36 hips), infection (4 hips), ceramic fracture (4 hips), and femoral periprosthetic fracture (4 hips).

RESULTS

The mean Harris hip score improved from 56.6 preoperatively to 88.2 postoperatively at the last follow-up. All hips showed stable osteointegration and firm fixation. Complications involved four hips (8.3%); there was one case each of periprosthetic fracture, delayed union of osteotomy site, femoral perforation, and infection. One stem re-revision was performed for deep infection of the femoral side. The Kaplan-Meier survival rate was 97.6% at the final follow-up.

CONCLUSION

Revision hip arthroplasty using a cementless modular distal fixation femoral stem showed satisfactory initial firm fixation and mid- to long-term survival rate. Complications can be minimized by careful surgical planning and meticulous procedure.

Для цитирования: Kang Joon Soon, Na Yeop, Ko Bong Seong, Jeon Yoon Sang. Clinical outcomes and survival rate of cementless modular distal fixation femoral stem for revision hip arthroplasty: A minimum 6-year follow-up.. Journal of orthopaedic surgery (Hong Kong). 2018. DOI: 10.1177/2309499018812241.

Предметные рубрики MeSH