MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aos.13856

Медицинская библиотека · Acta ophthalmologica · 2018

Laser pointer maculopathy - on the rise?

Torp-Pedersen Tobias, Welinder Lotte, Justesen Birgitte, Christensen Ulrik Correll, Solborg Bjerrum Søren, La Cour Morten, Saunte Jon Peiter

Клинический случайМногоцентровое исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To report symptoms and ocular pathology in 13 patients exposed to light from laser pointers.

METHODS

We conducted a multi-centre consecutive case series from eight ophthalmology departments.

RESULTS

Eleven boys aged 9-15 years and two girls aged 7 (sister of one of the aforementioned boys) and 12 years, respectively, were included. Laser wavelengths were 572 nm (green), 450 nm (blue), and red laser of unknown wavelength. Output powers were between 5 and 5000 mW. Evaluation included slit lamp examination, colour fundus photography (CFP), and optical coherence tomography (OCT). All subjects complained of unilateral vision loss. Initial visual acuities in exposed eyes ranged from 0.05 to 1.0 Snellen equivalent or better. Nine subjects showed pathology on CFP and OCT abnormalities. One subject had a macular hole, which closed after vitrectomy. Long-term visual acuity ranged from 0.3 to 1.0 Snellen equivalent or better.

CONCLUSION

High-powered laser pointers have become readily available on the internet, and they have the potential to induce lasting visual loss. More than half of the published laser pointer maculopathy cases since the first incidence in 1999 have been published in 2014-2017. We suspect that incidence of exposure and subsequent visual loss is rising, and we encourage national legislators to regulate this market.

Для цитирования: Torp-Pedersen Tobias, Welinder Lotte, Justesen Birgitte, Christensen Ulrik Correll, Solborg Bjerrum Søren, La Cour Morten, Saunte Jon Peiter. Laser pointer maculopathy - on the rise?. Acta ophthalmologica. 2018. DOI: 10.1111/aos.13856.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.