Inadvertent Introduction of Tissue Coring Into Joints During Arthrocentesis: An Experimental Study.

Xu Chi, Peng Haiwen, Chai Wei, Li Xiang, Li Rui, Chen Jiying

СтатьяПеревод в очереди

Аннотация

BACKGROUND The aim of this study was to investigate whether needles introduce skin plugs into joints during arthrocentesis. MATERIAL AND METHODS In the first part of this study, the arthrocentesis site was scrubbed with a fluorescein sodium swab, and 90 needles were inserted through the joint tissue and collected for examination under a fluorescence microscope. In the second part of this study, the joints were injected using 720 needles of different gauges. Two different randomly assigned needle insertion techniques were used: needle insertion straight through the joint capsule (subgroup 1) or insertion of the needle into the subcutaneous tissue followed by flushing of the needle with 0.5 mL of 0.9% normal saline prior to advancing the needle through the joint capsule (subgroup 2). RESULTS Of the 90 needle tips examined in the first part of this study, 21 had high-grade fluorescein contamination. In the second part of this study, the incidence of tissue, epidermis, and dermis contamination in subgroup 1 was 57.2%, 43.1%, and 25.0%, respectively. There was no significant difference in the incidence among different gauge needles, except for a difference in epidermis contamination between the 21-gauge and 23-gauge needles. Compared to subgroup 1, subgroup 2 had a significantly lower OR for tissue contamination. CONCLUSIONS It is common to introduce tissue coring with epidermis and dermis into the joint during arthrocentesis, which poses a potential risk for septic arthritis. However, tissue contamination of the joint may be reduced by flushing saline through the needle into the subcutaneous tissues prior to entering the joint capsule.

Для цитирования: Xu Chi, Peng Haiwen, Chai Wei, Li Xiang, Li Rui, Chen Jiying. Inadvertent Introduction of Tissue Coring Into Joints During Arthrocentesis: An Experimental Study.. Medical science monitor : international medical journal of experimental and clinical research. 2017. DOI: 10.12659/msm.905590.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.