MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0735-1097(99)00096-0

Медицинская библиотека · Journal of the American College of Cardiology · 1999

Bubble contrast echocardiography in detecting pulmonary arteriovenous shunting in children with univentricular heart after cavopulmonary anastomosis.

Chang R K, Alejos J C, Atkinson D, Jensen R, Drant S, Galindo A, Laks H

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

We sought to compare bubble contrast echocardiography and pulmonary angiography in detecting pulmonary arteriovenous malformation (PAVM) in children with cavopulmonary anastomosis (CPA), and to examine anatomic and physiologic variables associated with the development of PAVM.

BACKGROUND

Development of PAVM in patients with CPA may cause profound cyanosis. Pulmonary arteriovenous malformation has been traditionally diagnosed by pulmonary angiography with reported incidence of 20% to 25% in patients with CPA.

METHODS

Fourteen patients (age 1.1 to 12.6 years) with any forms of CPA and normal pulmonary venous drainage formed the study population. All patients underwent cardiac catheterization and pulmonary angiography. Bubble contrast echocardiographic studies were performed with injection of 10 ml of agitated saline solution into branch pulmonary arteries. Transthoracic echocardiograms using an apical view were performed to assess the appearance of bubble contrast in the systemic ventricles. We compared the results of pulmonary angiograms and contrast echocardiograms, and findings of contrast echocardiograms between lungs with hepatic venous blood flow and lungs without hepatic venous blood.

RESULTS

Ten of the 14 patients (71%) had positive contrast echocardiographic studies, compared with three (21%) detected by pulmonary angiograms (p = 0.01). No difference was found in pulmonary artery pressure, transpulmonary gradient or presence of heterotaxy syndrome between patients with positive contrast echocardiographic studies and patients with negative studies. However, patients with positive contrast echocardiograms tended to have lower oxygen saturation (81%) and higher hemoglobin (16.4 g/dl) compared with patients with negative studies (88% and 14.7 g/dl, p = 0.10 and p = 0.18 respectively). Patients with Glenn shunt or unidirectional Fontan had higher incidence of PAVM (10/11) compared with patients with classic or lateral tunnel Fontan (0/3, p = 0.01). All 12 lungs with no perfusion of hepatic venous blood had positive contrast echocardiographic studies. Lungs with no hepatic venous blood flow were more likely to develop PAVM compared with lungs with hepatic venous blood flow (12/12 and 3/16 respectively, p < 0.01).

CONCLUSIONS

Bubble contrast echocardiography is more sensitive in detecting PAVM compared with pulmonary angiography. The prevalence of PAVM in patients with CPA may be much higher than what had been reported previously. Lungs with no hepatic venous blood flow are more likely to develop PAVM than lungs with hepatic venous blood flow.

Для цитирования: Chang R K, Alejos J C, Atkinson D, Jensen R, Drant S, Galindo A, Laks H. Bubble contrast echocardiography in detecting pulmonary arteriovenous shunting in children with univentricular heart after cavopulmonary anastomosis.. Journal of the American College of Cardiology. 1999. DOI: 10.1016/s0735-1097(99)00096-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.