Медицинская библиотека · Journal of cardiovascular medicine (Hagerstown, Md.) · 2008

Short-term electrogeometric atrial remodelling after percutaneous atrial septal defect closure.

Santoro Giuseppe, Pascotto Marco, Caputo Salvatore, Gaio Gianpiero, Iacono Carola, Caso Ilaria, Sarubbi Berardo, Carrozza Marianna, Russo Maria Giovanna, Calabrò Raffaele

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Atrial arrhythmias are well known long-term complications of atrial septal defect (ASD), presumably due to chronic atrial enlargement and stretch. Surgical repair often fails to revert the arrhythmic risk despite atrial volumetric unloading, maybe as a consequence of atriotomic scar. Avoiding atrial incision, percutaneous ASD closure should result in atrial unloading and arrhythmic risk decrease. This study evaluated the atrial short-term electrogeometric effects of percutaneous ASD closure.

METHODS

Fifteen asymptomatic patients (age 23 +/- 5 years) submitted to percutaneous closure of large ASD (QP/QS 2.4 +/- 0.3) using the Amplatzer Septal Occluder device (24 +/- 2 mm) underwent atrial echocardiographic (indexed right atrial size and left atrial size as well as right atrial/left atrial volume ratio) and electrocardiographic (P-wave duration and dispersion, PR conduction time and dispersion) evaluation at 1 and 6 months after ASD closure.

RESULTS

After 6 months, the indexed right atrial volume and the right atrial/left atrial volume ratio had significantly decreased (from 39 +/- 5 to 20 +/- 2 ml/m2, P < 0.001 and from 2.0 +/- 0.2 to 1.0 +/- 0.1, P < 0.0001, respectively) as did the P-wave dispersion (from 32 +/- 2 to 28 +/- 1 ms, P = 0.03) despite a significant increase of both P-wave maximal (from 75 +/- 3 to 81 +/- 3 ms, P < 0.01) and minimal (from 42 +/- 3 to 53 +/- 3 ms, P < 0.005) duration.

CONCLUSION

Percutaneous ASD closure causes a short-term positive atrial electrogeometric remodelling. The electrocardiographic predictors of atrial arrhythmias, however, tend to worsen early after device implantation despite a marked volumetric unloading, possibly due to a 'foreign body' effect of the occluding device. This might warrant a closer follow-up during the first few weeks after device implantation.

Для цитирования: Santoro Giuseppe, Pascotto Marco, Caputo Salvatore, Gaio Gianpiero, Iacono Carola, Caso Ilaria, Sarubbi Berardo, Carrozza Marianna, Russo Maria Giovanna, Calabrò Raffaele. Short-term electrogeometric atrial remodelling after percutaneous atrial septal defect closure.. Journal of cardiovascular medicine (Hagerstown, Md.). 2008. DOI: 10.2459/jcm.0b013e3282f4c87b.