Assessment of biventricular functional reserve and NT-proBNP levels in patients with RV volume overload after repair of tetralogy of Fallot at young age.

van den Berg Jochem, Strengers Jan L M, Wielopolski Piotr A, Hop Wim C, Meijboom Folkert J, de Rijke Yolanda B, Boomsma Frans, Bogers Ad J J C, Pattynama Peter M T, Helbing Willem A

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To assess biventricular functional reserve (FR), NT-proBNP levels and exercise performance, in relation to right ventricular volume in patients with pulmonary regurgitation (PR) after repair of tetralogy of Fallot (TOF) at young age.

METHODS

In 53 TOF patients (maximum age at repair 2.0 years, interval since repair 15 (5) years) without residual lesions except PR, biventricular FR (derived from magnetic resonance imaging with dobutamine stress), NT-proBNP levels, maximal workload, and peak oxygen uptake were assessed.

RESULTS

Mean right ventricular end-diastolic volume was 140(38) ml/m(2). Median pulmonary regurgitant fraction was 37% (range 0-57%). Biventricular systolic stress response was normal: mean (SD) ESV decreased (DeltaRVESV -17(8) ml/m(2), DeltaLVESV -11(5)), SV increased (DeltaRVSV +12(9) ml/m(2), DeltaLVSV +9(6)), FR was positive in all (RV-FR +11(5)%, LV-FR +13(6)). No serious adverse effects to dobutamine were encountered. NT-proBNP was increased in 2 patients. Median level was 10 pmol/L (range 2-42). NT-proBNP correlated with PR-percentage but not with right ventricular size. High-risk levels of NT-proBNP indicated a smaller RV-FR and a smaller decrease of biventricular ESV. Mean (SEM) VO2(max) was 96(3)%, mean Workload(max) 89(2)% of predicted.

CONCLUSION

At mid to long term follow-up overall NT-proBNP levels are normal and biventricular functional reserve and exercise tolerance are well preserved in TOF repaired at young age, irrespective of RV volume. This questions the validity of isolated PR or RV volume criteria for pulmonary valve replacement in this group. Low-dose dobutamine stress testing is well tolerated and may be a useful additional tool for clinical decision making.

Для цитирования: van den Berg Jochem, Strengers Jan L M, Wielopolski Piotr A, Hop Wim C, Meijboom Folkert J, de Rijke Yolanda B, Boomsma Frans, Bogers Ad J J C, Pattynama Peter M T, Helbing Willem A. Assessment of biventricular functional reserve and NT-proBNP levels in patients with RV volume overload after repair of tetralogy of Fallot at young age.. International journal of cardiology. 2008. DOI: 10.1016/j.ijcard.2008.01.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.