MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/jamanetworkopen.2025.1412

Медицинская библиотека · JAMA network open · 2025

External Validation of the Phoenix Sepsis Score in Children With Suspected Community-Acquired Sepsis.

Long Elliot, Borland Meredith L, George Shane, Jani Shefali, Tan Eunicia, Phillips Natalie, Kochar Amit, Craig Simon, Lithgow Anna, Rao Arjun, Dalziel Stuart, Oakley Ed, Hearps Stephen, Gelbart Ben, McNab Sarah, Balamuth Fran, Weiss Scott L, Kuppermann Nathan, Brad Charlotte, Williams Amanda, Babl Franz E, Paediatric Research in Emergency Departments International Collaborative (PREDICT) Network

СтатьяМногоцентровое исследованиеВалидационное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

IMPORTANCE

The novel Phoenix Sepsis Score and sepsis criteria were derived and validated using a multicountry dataset and proposed as a new definition for sepsis in children.

OBJECTIVE

To externally validate the Phoenix Sepsis Score and sepsis criteria in a cohort of children hospitalized with suspected community-acquired sepsis.

DESIGN, SETTING, AND

PARTICIPANTS

This diagnostic study used data from the multicenter, multicountry Sepsis Epidemiology in Australian and New Zealand Emergency Departments (SENTINEL) study, collected from 2021 to 2023 and including 90-day follow-up. Children admitted to the hospital through 11 emergency departments in Australia and New Zealand and treated with parenteral antibiotics with either (1) a provisional diagnosis of sepsis or (2) treatment for sepsis (intravenous fluid bolus to treat poor perfusion) were included.

EXPOSURE: Development of organ dysfunction over the first 24 hours of hospitalization.

MAIN OUTCOMES AND MEASURES: The main outcomes were (1) in-hospital mortality and (2) death or requirement for extracorporeal life support (ECLS) within 72 hours of hospitalization.

RESULTS

A total of 6232 children were included in the analysis, with a median (IQR) age of 2.1 (0.3-7.1) years, 3386 (54.1%) male, in-hospital mortality of 60 (1.0%), and death or ECLS within 72 hours in 36 (0.6%). In this population, the worst Phoenix Sepsis Score calculated over the first 24 hours of hospitalization had an area under the precision recall curve of 0.17 (95% CI, 0.07-0.28) for predicting in-hospital mortality and 0.23 (95% CI, 0.11-0.36) for predicting death or ECLS within 72 hours. Overall, 306 children (4.9%) met the Phoenix sepsis criteria, of whom 33 (10.8%) died in the hospital (nearly half of the total number who died) and 28 (9.2%) died or required ECLS within 72 hours. The Phoenix sepsis criteria had a sensitivity of 55.0% (95% CI, 41.6%-67.9%) and positive predictive value (PPV) of 10.8% (95% CI, 7.6%-14.9%) for in-hospital mortality and sensitivity of 77.8% (95% CI, 60.8%-89.9%) and PPV of 9.2% (95% CI, 6.2%-13.0%) for death or ECLS within 72 hours. Coagulation data for the calculation of the Phoenix Sepsis Score were missing in more than 85% of children.

CONCLUSIONS AND RELEVANCE: In this multicenter diagnostic study of children hospitalized with suspected sepsis, the Phoenix Sepsis Score and sepsis criteria had similar performance to the original derivation and validation cohorts. The small proportion of children meeting Phoenix sepsis criteria, missingness of data, timing of application, and lack of sensitivity for in-hospital mortality limit the clinical utility of the criteria.

Для цитирования: Long Elliot, Borland Meredith L, George Shane, Jani Shefali, Tan Eunicia, Phillips Natalie, Kochar Amit, Craig Simon, Lithgow Anna, Rao Arjun, Dalziel Stuart, Oakley Ed, Hearps Stephen, Gelbart Ben, McNab Sarah, Balamuth Fran, Weiss Scott L, Kuppermann Nathan, Brad Charlotte, Williams Amanda, Babl Franz E, Paediatric Research in Emergency Departments International Collaborative (PREDICT) Network. External Validation of the Phoenix Sepsis Score in Children With Suspected Community-Acquired Sepsis.. JAMA network open. 2025. DOI: 10.1001/jamanetworkopen.2025.1412.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.