MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1024/0301-1526/a000712

Медицинская библиотека · VASA. Zeitschrift fur Gefasskrankheiten · 2018

Stent fractures after common femoral artery bail-out stenting due to suture device failure in TAVR.

Veulemans Verena, Afzal Shazia, Ledwig Paul, Heiss Christian, Busch Lucas, Sansone Roberto, Soetemann Dagmar B, Maier Oliver, Kleinebrecht Laura, Kelm Malte, Zeus Tobias, Hellhammer Katharina

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Vascular access site-related complications are frequent in the context of transfemoral transcatheter aortic valve replacement (TAVR). The implantation of a covered stent graft is an effective treatment option for bleeding control. However, the external iliac and common femoral arteries are exposed to flexion of the hip joint. Therefore, stent compression and stent/strut fractures may occur, facilitating stent occlusion.

PATIENTS AND

METHODS

In all 389 patients who received transfemoral TAVR from 2013-2015 at the Düsseldorf Heart Centre, we monitored the management of vascular access site-related complications. Our analyses focused on immediate technical success and bleeding control, primary patency, and the occurrence of stent/strut fractures after six to 12 months of follow-up.

RESULTS

Vascular access site-related complications occurred in 13 % (n = 51), whereof in 10 patients, the bleeding was successfully managed by prolonged compression. In 40 out of 51 patients, a covered stent graft was implanted in the common femoral artery, leading to 100 % immediate bleeding control. After a mean follow-up of 334 ± 188 days, 28 stents out of 29 patients with completed follow-up (excluding e. g. death) were without flow-limiting stenosis (primary patency 97 %) or relevant stent compression (diameter pre/post 8.6/8.1 mm, p = 0.048, late lumen loss 1.1 ± 0.2 mm, mean flow velocity 92 ± 34 cm/s). In four asymptomatic patients, stent/strut fractures were detected (14 %) without flow-limiting stenosis.

CONCLUSIONS

The implantation of a covered stent graft is highly effective and safe to control vascular access site-related complications after TAVR. Stent/strut fractures in the flexible segment of the common femoral artery may occur, as consequently verified by X-ray visualization, but show no impairment on flow or clinical parameters after six to 12 months.

Для цитирования: Veulemans Verena, Afzal Shazia, Ledwig Paul, Heiss Christian, Busch Lucas, Sansone Roberto, Soetemann Dagmar B, Maier Oliver, Kleinebrecht Laura, Kelm Malte, Zeus Tobias, Hellhammer Katharina. Stent fractures after common femoral artery bail-out stenting due to suture device failure in TAVR.. VASA. Zeitschrift fur Gefasskrankheiten. 2018. DOI: 10.1024/0301-1526/a000712.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.