DOI 10.1016/j.mri.2006.02.002

Медицинская библиотека · Magnetic resonance imaging · 2006

Measurement of regional brain temperature using proton spectroscopic imaging: validation and application to acute ischemic stroke.

Marshall Ian, Karaszewski Bartosz, Wardlaw Joanna M, Cvoro Vera, Wartolowska Karolina, Armitage Paul A, Carpenter Trevor, Bastin Mark E, Farrall Andrew, Haga Kristin

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A magnetic resonance proton spectroscopic imaging (SI) technique was developed to measure regional brain temperatures in human subjects. The technique was validated in a homogeneous phantom and in four healthy volunteers. Simulations and calculations determined the theoretical measurement precision as approximately +/-0.3 degrees C for individual 1-ml voxels. In healthy volunteers, repeated measurements on individual voxels had an S.D. = 1.2 degrees C. In a clinical study, 40 patients with acute ischemic stroke were imaged within 26 h (mean, 10 h) of onset. Temperatures were highest in the region that appeared abnormal (i.e., ischemic) on diffusion-weighted imaging (DWI) compared with a normal-appearing brain. The mean temperature difference between the DWI "lesion" area and the "normal brain" was 0.17 degrees C [P < 10(-3); range, 2.45 degrees C (hotter)-2.17 degrees C (cooler)]. Noninvasive temperature measurement by SI has sufficient precision to be used in studies of pathophysiology in stroke and in other brain disorders and to monitor therapies.

Для цитирования: Marshall Ian, Karaszewski Bartosz, Wardlaw Joanna M, Cvoro Vera, Wartolowska Karolina, Armitage Paul A, Carpenter Trevor, Bastin Mark E, Farrall Andrew, Haga Kristin. Measurement of regional brain temperature using proton spectroscopic imaging: validation and application to acute ischemic stroke.. Magnetic resonance imaging. 2006. DOI: 10.1016/j.mri.2006.02.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.