Reinforced closure of the sternum with absorbable pins for high-risk patients.
Аннотация
We report our result of the reinforced sternal closure in 51 consecutive patients. We applied a new type of absorbable radiopaque pins (Super FIXSORB) composed of poly-lactide acid and hydroxyapatite, in addition to conventional stainless steel wires. The risk scores of our patients were calculated from the simplified risk scoring system for major infection based on the Society of Thoracic Surgeons National Cardiac Database. The expected probability of infection is significantly higher than the actual infection rate in our patients. Our procedure may contribute to minimizing the fatal sternal complication particularly in high-risk patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.