[Risk factors for early arrhythmias post transcatheter closure of perimembranous ventricular septal defects].

Аннотация на английскомСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhu Xian-yang, Liu Yu-hao, Hou Chuan-ju, Han Xiu-min, Sheng Xiao-tang, Zhang Duan-zhen, Cui Chun-sheng, Wang Qi-guang, Deng Dong-an, Zhang Yu-wei

Аннотация

OBJECTIVE: To analyze the risk factors for early arrhythmias after transcatheter closure of perimembranous ventricular septal defect (PVSD).

METHODS: A total of 358 patients [161 males, aged from 3 to 54, mean (10.9 +/- 8.1) years, body weight from 12 to 90, mean (32.8 +/- 17.2) kg] who underwent transcatheter closure of PVSD from August 2002 to February 2006 were included in this retrospective analysis. Electrocardiogram was performed daily after transcatheter closure for seven days. Relationships between arrhythmias and those risk factors such as the defect characteristics and the device size and types were explored by logistic regression analysis. Left ventriculography showed 195 out of 358 patients with PVSD were complicated with membranous aneurysm. The PVSD diameter ranged from 2 to 18 (6.5 +/- 3.1) mm in left ventricular side and from 2 to 12 (4.2 +/- 2.3) mm in right ventricular side. A total of 140 nonsymmetrical and 218 symmetrical occluders with diameter 4 to 18 (8.1 +/- 2.5) mm were used to close those defects.

RESULTS: Procedure was successful in all patients. Early arrhythmias after transcatheter closure of PVSD were observed in 135 (37.7%) patients and serious cardiac arrhythmias in 23 (6.4%) patients. The early arrhythmias after transcatheter closure of PVSD were significantly correlated with device size [> or = (8.6 +/- 2.7) mm] and type (nonsymmetrical device), the span between the defect and tricuspid (< or = 3 mm), and the presence of aneurysm.

CONCLUSION: Larger device size, nonsymmetrical device, narrow span between the defect and tricuspid and the presence of aneurysm are the risk factors for early arrhythmias after transcatheter closure of PVSD.